Compactflash Memory Card; Led Behavior - Enterasys X-Pedition XSR-3150 Getting Started Manual

Security router
Hide thumbs Also See for X-Pedition XSR-3150:
Table of Contents

Advertisement

CompactFlash Memory Card

The optional plug-in CompactFlash (CF) memory card, shown in
chip controller and flash memory modules in a matchbook-sized package with a 50-pin, PCMCIA
connector consisting of two rows of 25 female contacts each.
The PCMCIA male interface supports both Type I and Type II CF cards. Note that the CF release
mechanism pops out when you install the card. For installation instructions, refer to the Hardware
Installation chapter.

LED Behavior

The 14 LEDs on the XSR front panel display system and port status as described in
six system LEDs are illustrated to the left and the eight GigabitEthernet LEDs to the right in
Figure
A-28. Note that Link and TX (transmit) green LEDs are provided for the GBIC (optical) port
while each GigabitEthernet port has one green and one amber LED.
LED
NIM 1, NIM 2
SYS(tem Status)
PWR
Figure A-27
Pin 1
NIM1
NIM2
SYS
VPN
PWR
COM
Table A-3 LED Description
State
ON
OFF
ON
OFF
Blinking
ON
OFF
Cable, CompactFlash and Accessory Specifications
CompactFlash Memory Card
Figure A-28
XSR LEDs
Function
T1/E1, ISDN or HSSI card is present and power-
up diagnostics test passed
NIM slot empty or power-up diagnostics test failed
XSR is operational
Faulty hardware or Bootprom
Flash update is in progress (software image
downloading), warning you not to power down the
XSR. Powering down now can leave the branch
router without valid software.
XSR is powered up and Bootrom initialized
XSR is powered down
Figure
A-27, comprises a single