TO CLEAN
BATTERY
AND TERMINALS
Corrosion
and dirt on the battery
and termi-
nals can cause the battery
to "leak" power.
1.
Disconnect
BLACK
battery
cable first
then
RED
battery
cable
and remove
battery
from tractor.
2.
Rinse the battery
with plain water
and
dry.
3.
Clean
terminals
and battery
cable
ends
with wire brush
until bright.
4.
Coat terminals
with grease
or petro-
leum jelly.
5.
Reinstall
battery
(See "REPLACING
BATTERY"
in the SERVICE
AND AD-
JUSTMENTS
section
of this manual).
TRANSAXLE
COOLING
The transmission
fan and cooling
fins
should
be kept clean to assure
proper
cooling.
Do not attempt
to clean
fan or transmis-
sion while
engine
is running
or while
the
transmission
is hot. To prevent
possible
damage
to seals,
do not use high pressure
water
or steam
to clean
transaxle.
• Inspect
cooling
fan to be sure fan
blades
are intact
and clean.
• Inspect
cooling
fins for dirt, grass
clip-
pings and other
materials.
To prevent
damage
to seals,
do not use com-
pressed
air or high pressure
sprayer
to
clean cooling
fins.
TRANSAXLE
PUMP
FLUID
The transaxle
was sealed
at the factory
and fluid maintenance
is not required
for the life of the transaxle.
Should
the
transaxle
ever
leak or require
servicing,
contact
your
nearest
Sears
or other
quali-
fied service
center.
V-BELTS
Check
V-belts
for deterioration
and wear
after 100 hours
of operation
and replace
if necessary.
The belts are not adjustable.
Replace
belts if they begin to slip from
wear.
ENGINE
LUBRiCATiON
Only use high quality
detergent
oil rated
with API service classification
SG-SL,
Select
the oil's SAE viscosity
grade
according
to your expected
operating
temperature.
SAE VISCOSITY GRADES
F
-20
0
30
32
40
60
80
100
o -_o
-2;
-lo
;
;o
_o
_o
4o
TEMPERATURE
RANGE ANTICIPATED
BEFORE
NEXT OIL CHANGE
oil visc
chart1
e
NOTE:
Although
multi-viscosity
oils
(5W30,
10W30
etc.) improve
starting
in
cold weather,
they will result
in increased
oil consumption
when
used above
32°R
Check
your engine
oil level more frequent-
ly to avoid
possible
engine
damage
from
running
low on oil.
Change
the oil after every
50 hours
of op-
eration
or at least once
a year
if the tractor
is not used for 50 hours
in one year.
Check
the crankcase
oil level before
starting
the engine
and after each
eight
(8) hours
of operation.
Tighten
oil fill cap/
dipstick
securely
each time you check
the
oil level.
TO CHANGE
ENGINE
OIL
Determine
temperature
range
expected
before
oil change.
All oil must meet API
service
classification
SG-SL.
• Be sure tractor
is on level surface.
• Oil will drain more freely
when
warm.
• Catch
oil in a suitable
container.
1.
Remove
oil fill cap/dipstick.
Be careful
not to allow
dirt to enter the engine
when
changing
oil.
2.
Remove
yellow
cap from end of drain
valve
and install the drain tube onto
the fitting.
Oil Drain Valve
Closed
and
Locked
Position
Yellow Cap
Drain Tube
3.
Unlock
drain valve
by pushing
inward
slightly
and turning
counterclockwise.
4.
To open,
pull out on the drain valve.
5.
After
oil has drained
completely,
close
and lock the drain valve by pushing
inward
and turning
clockwise
until the
pin is in the locked
position
as shown.
6.
Remove
the drain tube
and replace
the
cap onto the end of the drain valve.
7.
Refill engine
with oil through
oil fill dip-
stick tube.
Pour slowly.
Do not overfill.
For approximate
capacity
see "PROD-
UCT SPECIFICATIONS"
section
of this
manual.
2O