Carrier HRVCCLHU Installation, Start-Up, And Operating Instructions Manual page 5

Heat recovery ventilator sizes 1150, 1200, 1250, and 1330
Hide thumbs Also See for HRVCCLHU:
Table of Contents

Advertisement

Cy
A99283
Fig. 8_HRVCCLHU
Conventional
Horizontal
Unit
Fig. 9---HRVCCSVU
Compact
Unit
A98408
Fig. 10---HRVCCLVU
Compact
High-Efficiency
Unit
COMPONENT
DESCRIPTION
The following listed items are components of HRVCCLHU.
(See
Fig. 8)
I. Stale air return from building connected
to return-air duct
system.
2. Fresh air intake connected to outdoor air inlet hood.
3. Exhaust air connected to outdoor air exhaust hood.
4. Mechanical filters trap dust contained in the air.
5. Heat recovery core is either a cross-flow type for compact
models+ or a counter-flow type for high efficiency models. The
core transfers heat between the 2 air streams.
6. Blowers bring in fresh air from outside and exhaust stale air to
outside.
7. Electronic control circuit ensures proper unit operation.
8. Fresh air supply from HRV connected to return air duct of
forced air system.
9. Terminal connector block for wiring wall and timer controls.
10. Electrical cord connects to standard I 15-v outlet.
The following
listed items are components of HRVCCSVU
and HRVCCLVU.
(See Fig. 9 and 10)
I. Stale air return from building connected
to return-air duct
system.
2. Fresh air intake connected
to outdoor air inlet hood.
3. Exhaust air connected
to outdoor air exhaust hood.
4. Dampers
are used to control air exchange with outdoor air
during defrost mode.
5. Mechanical
filters trap dust contained in the air.
6. Heat recovery
core is either a cross-flow type for compact
models, or a counter-flow
type for high efficiency models. The
core transfe_
heat between the 2 air streams.
7. Blowers bring in fresh air from outside and exhaust stale air to
ouLside.
8. Capacitor required for motor operation.
9. Condensation
tray collects condensate
from heat recovery
core.
I0. Drainage tubes connects to sleeved grommets
1 I. Electronic control circuit ensures proper unit operation.
12. Fresh air supply from HRV connected to return air duct of
forced air system.
13. Terminal connector
block for wiring wall and timer controls.
14. Electrical
cord
connects
to standard
115-v outlet.