Image (Toggle) Command; Direct On Setting Command; Direct On Cancel Command; Power Management Ready Command - Sanyo PLC-WL2500A Manual

Basic serial command specifications
Hide thumbs Also See for PLC-WL2500A:
Table of Contents

Advertisement

PLC-WL2500A/WL2501A/ WL2503 A Basic Serial Command Specifications

6.34. IMAGE (Toggle) Command

Command
"C27"[CR]
Switch Image Setting status.
Detail
This command works the same as "IMAGE" button of the remote control.
Acceptable
Response
Unacceptable

6.35. Direct on Setting Command

Command
"C28" [CR]
Enable Direct on.
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Acceptable
Response
Unacceptable

6.36. Direct on Cancel Command

Command
"C29" [CR]
Disable Direct on.
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Acceptable
Response
Unacceptable

6.37. Power Management Ready Command

Command
"C2A" [CR]
Set Power Management to Ready mode.
Detail
This status is stored in EEPROM and retained regardless of Power ON/OFF.
Acceptable
Response
Unacceptable

6.38. Power Management OFF Command

Command
"C2B" [CR]
Set Power Management to OFF mode.
Detail
This status is stored in EEPROM and retained regardless of Power ON/OFF.
Acceptable
Response
Unacceptable

6.39. Power Management Shut down Command

Command
"C2E" [CR]
Set Power Management to Shut down mode.
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Acceptable
Response
Unacceptable
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
[ACK] [CR]
"ÿ "[CR]
16/25