Meinberg TCR509 Operating Instructions Manual
Meinberg TCR509 Operating Instructions Manual

Meinberg TCR509 Operating Instructions Manual

Incl. software tcrmon time code receiver

Advertisement

Quick Links

Technical Data

Operating Instructions

TCR509
Incl. Software TCRMON
FUNKUHREN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TCR509 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Meinberg TCR509

  • Page 1: Operating Instructions

    FUNKUHREN Technical Data Operating Instructions TCR509 Incl. Software TCRMON...
  • Page 2: Impressum

    Impressum Werner Meinberg Auf der Landwehr 22 D-31812 Bad Pyrmont Telefon: 0 52 81 / 9309-0 Telefax: 0 52 81 / 9309-30 Internet: http://www.meinberg.de Email: info@meinberg.de 19th. of February 2003...
  • Page 3: Table Of Contents

    Updating the Firmware ............... 10 Replacing the Lithium-Battery ............10 Specifications ..................11 CE Label .................... 12 Format of the Meinberg Standard Time String ........13 Rear Connector Pin Assignments ............14 Pin Assignment ................... 15 Diskette with Software TCRMON ............. 16 The Program TCRMON.EXE ............
  • Page 5: Introduction

    Introduction In the early 1950's the use of coded timing signals for correlation of data began to take on widespread importance. Especially the U.S space and missile programs were the forces behind the development of new time codes. The definition of time code formats was completely arbitrary and left to the individual ideas of each design engineer.
  • Page 6: Function

    PPS signal is still synchronized by IRIG. Initial Time and date can be set by a standard Meinberg telegram via serial port COM0. TCR509 can re-calculate UTC from received IRIG-Time if there are no time zone changeovers (such as daylight saving) performed in the IRIG telegram.
  • Page 7: Setting Into Operation

    Setting into operation To obtain a correct operation of the TCR509, please pay attention to the following points. Supply Voltage The board only needs a single supply voltage of +5V. Source should be able to supply at least 200mA. Input Signals The IRIG-A/B signal must be applied to the SMB-Connector.
  • Page 8: Serial Port Configuration

    Serial Port Configuration Baudrate and framing for each of the both serial ports can be configured seperately by three dip switches. SW1-1 SW1-2 Baudrate 19200 9600 4800 2400 Baudrate of serial port COM0 SW1-3 Datenformat Framing of serial port COM0 SW1-5 SW1-6 Baudrate...
  • Page 9: Operating Mode Of The Serial Ports

    Each of the two serial ports is configurable separately for two operating modes. If the 'per second' mode is selected, the TCR509 automatically issues a Meinberg standard time string at the beginnig of every new second. When selecting the 'on request' mode TCR509 issues a timestring at the beginning of the next second after the character '?' (ASCII-Code 3Fh) was received.
  • Page 10: The Dcf Simulation Mode

    The DCF Simulation Mode In DCF-Simulation mode the TTL and current loop outputs provide a time mark signal similar to the signals transmitted by the german VLF time code transmitter DCF77. Within one minute a complete time code frame is transmitted. Since there are no timezone and leap second announcements in the IRIG time code, these announcement flags (daylight saving flag, leap second flag) are neglected.
  • Page 11: Updating The Firmware

    Updating the Firmware Whenever it is necessarry to upgrade the on-board software, the new firmware can be downloaded using the serial port COM0. If the /BOOT input, which is available on the 64 Pin VG-Connector, is pulled low during a power up reset, an internal bootstrap-loader is activated and waits for instruc- tions from the serial port COM0.
  • Page 12: Specifications

    Software watchdog generates reset in case of improper program execution Initialization: Initial time and date of hardware clock can be set by a Meinberg standard telegram via serial port COM0. Pulse Outputs: one PPS-Output, TTL Level, 200ms length, positive and inverted.
  • Page 13: Ce Label

    Serial modes: per second or on request Format of serial time string: Meinberg Standard Telegram Connectors: 64 Pin VG-Connector Coax RF-Connector (SMB) Supply voltage: +5V, abt. 200mA when option 'LED-Display' is installed Dimensions: Eurocard 100mm x 160 mm, 1,5mm Epoxy Ambient Temperature: 0...50°C...
  • Page 14: Format Of The Meinberg Standard Time String

    Format of the Meinberg Standard Time String The Meinberg Standard Time String is a sequence of 32 ASCII characters starting with the STX (start-of-text) character and ending with the ETX (end-of-text) character. The format is: <STX>D:dd.mm.yy;T:w;U:hh.mm.ss;uvxy<ETX> The letters printed in italics are replaced by ASCII numbers whereas the other characters are part of the time string.
  • Page 15: Rear Connector Pin Assignments

    Rear Connector Pin Assignments Name Description 32a+c Ground VCC in (+5V) 1a+c +5V Supply Voltage P_SEC out PPS-Signal, TTL-Level, length 200msec /P_SEC out PPS-Signal, TTL-Pegel, length 200ms inverted GEN_TTL1 DCF-Simulation or PPS-Signal, TTL-Level GEN_TTL2 DCF-Simulation or PPS-Signal, TTL-Level GEN_TTL3 DCF-Simulation or PPS-Signal, TTL-Level GEN_TTL4 DCF-Simulation or PPS-Signal, TTL-Level GEN_OPT1+...
  • Page 16: Pin Assignment

    Pin Assignment VCC in (+5V) VCC in (+5V) /BOOT /P_SEC P_SEC Reserve GEN_OUT3- GEN_OUT3+ GEN_OUT4- GEN_OUT4+ TIME_SYN GEN_OUT2- GEN_OUT2+ GEN_OUT1- GEN_OUT1+ COM1 TxD COM0 TxD GEN_TTL2 GEN_TTL4 GEN_TTL3 GEN_TTL1 COM1 RxD COM0 RxD...
  • Page 17: Diskette With Software Tcrmon

    Diskette with Software TCRMON...
  • Page 18: The Program Tcrmon.exe

    The Program TCRMON.EXE The program TCRMON was designed to monitor and control all functions of the Meinberg IRIG-Time Code Reader TCR509. TCRMON is executable in a Win9x and WinNT environment. To install TCRMON just start Setup.exe from the enclosed Disk and follow the instructions of the installation program.
  • Page 19: The Main Window

    The Main Window The main window provides an overview of all essential data like time, date, etc. Time,Date,Weekday: Show time, date and day of week. The displayed time is extended by a 'U' if the serial timestrings UTC-Timezone identifier is enabled. Local Offset: Shows the offset from local time to UTC Ser.
  • Page 20: Setting The Local Offset From Utc

    Checkbox Enable UTC String Indicator selects whether the UTC Identifier shall appear in the issued timestrings. (s. Chapter Format of Standard Meinberg Timestring ). When using a Meinberg-Driver to synchronize a PC, the correct UTC offset must be entered and the UTC identifier must be enabled.
  • Page 21: Menu Help

    Menu Help This window shows information about the current release of TCRMON and the system ressources.

Table of Contents