M e s s a g e s
Display readout
AUT O
(Automatic protocol
detection error)
LER R
(Lamp error)
MER R
(Memory error)
CSE R
(Check-sum error)
****
(Short error)
ShE R
(Hot lamp)
Hot
(Base temperature error)
bTE R
HTE R
(Head temperature
error)
FbE P
(Feedback error pan)
FbE T
(Feedback error tilt)
FbE R
(Feedback error pan/tilt)
PAE R
(Pan time-out)
TIE R
(Tilt time-out)
C1E R
(Color wheel 1 time-out)
C2E R
(Color wheel 2 time-out)
FgE R
(Fixed gobo time-out)
(Rot. gobo time-out)
RgE R
Appears if...
... automatic protocol detection is enabled
but the protocol (Martin/DMX) cannot be
determined because there is no control
data.
... the lamp doesn't ignite within 10 min-
utes of receiving the 'Lamp ON' com-
mand. Likely reasons are a missing or
defective lamp, or insufficient AC voltage.
...the EEPROM memory cannot be read.
...a software upload is unsuccessful.
... there is no communication between the
control panel and motherboard. This
readout appears briefly when switching
on the fixture.
... the fixture detects the lamp is ON but
no 'Lamp ON' command has been
received. This can occur if the lamp relay
is stuck or if the lamp-power feedback cir-
cuit fails. The fixture may be operated but
remote lamp on/off may be effected.
... you attempt to strike the lamp within 8
minutes after having switched it off. The
fixture will store the 'Lamp ON' instruction
and strike the lamp once the 8 minutes
period has elapsed.
...there is a malfunction in the base or
head temperature sensing circuit.
...pan (FbEp), tilt (FbET) or both (FbER)
feedback circuits are malfunctioning. It
will still be possible to operate the fixture,
though it goes into a "safe" mode where
maximum speed is reduced, thus prevent-
ing the fixture from losing track of its
home position (losing step).
...the pan or tilt indexing circuit is malfunc-
tioning. The fixture will, after the time-out,
establish a mechanical stop, and continue
to work normally.
...the magnetic-indexing circuit malfunc-
tions (e.g. sensor defective or magnet
missing). After the time-out, the effect in
question stops in a random position.
Appendices
What to do
•
Verify that the controller is sending
and the serial link is properly con-
nected.
•
Check the lamp
•
Check that the voltage and fre-
quency settings match the local
supply.
•
Contact Martin service personnel
for assistance.
•
Reload software, see page 23.
•
Check fuses and replace accord-
ingly.
•
Check that cable between control
panel and motherboard is con-
nected properly.
•
Reinstall software.
•
Contact Martin service personnel
for assistance.
•
Wait until the lamp strikes.
•
Contact Martin service personnel
for assistance.
•
Contact Martin service personnel
for assistance.
•
Contact Martin service personnel
for assistance.
•
Contact Martin service personnel
for assistance.
31
Need help?
Do you have a question about the MAC 500 and is the answer not in the manual?