Installation instructions
[] PROVIDE ADEQUATE
GAS
SUPPLY
Your range
is designed
to operate
at a pressure
of 5" of
water
column
on naturM gas or, if designed
for LP gas
(propm_e
or butane),
10" of water
column.
Make sure vou are supplying
your range
with tile type
of gas tot which
it is designed.
This range
is convertible
for use on natural
or
propane
gas. If you decide
to use this range
on I,P gas,
conveiMon
must
be made
bv a qualified
I,P installer
before
attempting
to operate
tile range
on that gas.
For proper
operation,
tile pressure
of natural
gas
supplied
to tile regulator
must
be between
5" and
13"
of water
cohmm.
For I,P gas, tile pressure
supplied
must be between
10"
and l 3" of water colmnn.
When
checking
fi)r proper
operation
of tile regulatm;
tile inlet pressure
Illtlst be at least 1" greater
than
tile
operating
(nmnifl_ld)
pressure
as given above.
Tile pressure
regulator
located
at tile inlet
of tile range
manifold
must
remain
in the supply
line regardless
of
whether
natural
or I,P gas is being
used.
A flexible
metal
appliance
connector
used to connect
tile range
to tile gas supply
line should
have an I.D. of
1/2"
and be 5 leer in length
tier ease of installation.
In
Canada,
flexible
connectors
must be single
wall metal
connectors
no hmger
than
6 teet
in length.
[] CONNECT
THE RANGE TO GAS
Shut
off
the
main
gas supply
valve
before
discmmecting
the
old
range
and leave
it off
until
the
new
hook-up
has
been
completed.
Don't
forget
to relight
the
pilot
on
other
gas applimaces
when
you
turn
the
gas back
on.
Because
hard
piping
restricts
nmvement
of tile range,
tile use of a CSA International-certified
flexible
metal
appliance
connector
is recommended
unless
local
codes
require
a hard-piped
connection.
Never
use an old connector
when
installing
a new
range.
If tile hard
piping
method
is used, you must
careflllly
align tile pipe;
tile range
cannot
be moved
after
the connection
is made.
To prevent
gas leaks,
put pipe joint
comi)otmd
on, or
wrap pipe
thread
tape
with Teflon'::
around,
all male
(external)
pipe
threads.
A. Install
a inanual
gas
line
shut-off
valve
in tile
gas line
in an
easily
accessed
location
outside
of the
range.
Make
sure
everyone
operating
tile
range
knows
where
and
how
to shut
ott
tile
gas supply
to tile
range.
Install
male
1/2"
flare
union
adapter
to tile 1/2"
NPT internal
thread
at inlet of regulator.
Use a
backup
wrench
on tile regulator
fitting
to avoid
danmge.
When
installing
tile range
fl'om
tile fl'ont,
remove
the 90 ° elbow
fi_r easier
installation.
Install
male
1/2"
or 3/4"
flare union
adapter
to tile
NPT internal
thread
of tile inanual
shut-off
valve,
taking
care
to back-up
tile shut-off
valve to kee I) it
fl'onl
turning.
Connect
flexible
tnetal
ai)pliance
connector
to tile
adapter
on tile
range.
Position
range
to l)erlnit
connection
at the
shut-off
wflve,
E. When
all connections
have been
inade,
inake
sure
all range
controls
are in tile off position
and turn
oil
the main
gas supply
wdve.
Llse a liquid
leak detector
at all joints
and
connections
to check
fi_r leaks in the
s_istei//.
WARNING:
oo NOTUSEA
FLAME
TO
CHECK
FOR
GAS LEAKS.
When
using
test
pressures
greater
than
1/2
psig
to
pressure
test tile
gas supply
s)_steln
of tile residence,
disconnect
tile
range
and
individual
shut-off
valve
fl'oln
tile gas
supply
piping.
When
using
test
pressures
of 1/2
psig
or less
to test
the
gas supply
system,
simply
isolate
tile
range
from
tile
gas supply
system
by closing
tile
individual
sh m-off
wflve.
*Teflon:
Registered
trademark
of DuPont