VFDR(18,24,30)LB LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING, smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance
Do not touch any electrical switch; Do not use any
phone in your building
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
1.
STOP! Read the safety information above on this label.
2. Set REMOTE/OFF/ON switch to "OFF".
3. Turn off all electric power to the
appliance (if applicable).
4. Open bottom louver assembly (if
applicable).
5. Push in gas control knob slightly
and turn clockwise
"OFF".
NOTE: Knob cannot be turned from "PILOT"
to "OFF" unless knob is pushed in slightly.
Do not force.
6. Wait ten (10) minutes to clear
out any gas. Then smell for gas,
including near the floor. If you
smell gas, STOP! Follow "B" in
the safety information above. If
you do not smell gas, go to the next
step.
7. Find pilot - Follow metal tube from
gas control. The pilot is located next to the burner, near the
right side.
1. Set REMOTE/OFF/ON switch to OFF.
2. Turn off all electric power to the appliance if service is to be
performed (if applicable).
3. Open bottom louver assembly (if applicable).
Page 16
causing property damage, personal injury or loss of life.
LIGHTING INSTRUCTIONS
GAS CONTROL KNOB
GAS CONTROL KNOB
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
SHOWN IN "OFF" POSITION.
to
SHOWN IN "OFF" POSITION.
REMOTE
REMOTE
REMOTE
OFF
OFF
OFF
ON
ON
ON
PILOT
PILOT
PILOT
THERMOPILE
THERMOPILE
THERMOPILE
THERMOCOUPLE
THERMOCOUPLE
THERMOCOUPLE
(LPG)
(LPG)
(LPG)
THERMOCOUPLE
THERMOCOUPLE
THERMOCOUPLE
(NATURAL)
(NATURAL)
(NATURAL)
TO TURN OFF GAS TO APPLIANCE
If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service tech-
nician. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
8.
Turn gas control knob counterclockwise
to "PILOT".
9. Push in control knob all the way and hold in. Repeatedly push
the Piezo Ignitor Button until the pilot is lit. Continue to hold
the control knob in for about one (1) minute after the pilot is
lit. Release knob, and it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 5 through 9.
If knob does not pop up when released, STOP and IM-
MEDIATELY call a qualified service technician or gas
supplier.
If the pilot will not stay lit after several tries, turn the gas
control knob to "OFF" and call your service technician
or gas supplier.
10. Turn gas control knob counterclockwise
ELECTRODE
ELECTRODE
ELECTRODE
11. Close bottom louver assembly (if applicable).
12. Turn on all electric power to the appliance (if applicable).
13. Set REMOTE/OFF/ON switch to desired setting.
4. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
5. Close bottom louver assembly (if applicable).
to "ON".