(3) Remove the three screws from the underside of the scanner base.
(4) Insert the tip of a flat screwdriver into each of the four holes provided in the scanner base and
unhook the four latches while lifting up the control panel ASSY.
(5) Disconnect the panel harness from the control panel PCB. (For the disassembly procedure of
the control panel ASSY, refer to page IV-24.)
n n n n
Reassembling Notes
When reinstalling the scanner unit, fit the holes and cutouts provided in the scanner unit over
screws "A" and pawls of the scanner mount, respectively, and then slide the scanner unit to the
front. (Refer to page IV-17.)
When connecting the CCD motor harness, panel harness, and scanner HP sensor harness to
the relay PCB, route them as shown below.
Scanner HP sensor harness
Document sensor harness
Panel harness
Speaker harness
Main-relay (panel) harness
Relay PCB
IV - 18
CCD flat cable
ADF motor harness
CCD motor harness
Main-relay (motors) harness
Main-relay (CCD) harness