Download Print this page

EMI UNH-T2H-T3H-T4H Specifications

Emi corp. universal air handler multi-zone limited range heat pump specification sheet

Advertisement

Quick Links

JOB NAME: _____________________________________ LOCATION: _______________________________________
PURCHASER: _____________________________________________________________________________________
ENGINEER: _______________________________________________________________________________________
SUBMITTED TO: _________________________________ FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ]
SUBMITTED BY: _________________________________ DATE:____________________________________________
UNIT DESIGNATION: SCHEDULE #: _______________ MODEL #: ________________________________________
Manufacturer reserves the right to change these specifications at any time without incurring obligation.
Performance:
Performance certified in accordance with ARI 210/240
cooling
Indoor design conditions: 80°F Dry Bulb / 67°F Wet Bulb
Outdoor design conditions: 95°F
Heating
Indoor design conditions: 70°F Dry Bulb / 57°F Wet Bulb
Outdoor design conditions (High): 47°F Dry Bulb / 43°F Wet Bulb
Model
Indoor Air
Outdoor
Handler
T2H8800
(2) UNH24
T2H8400
(2) UNH24
T2H4400
(2) UNH24
(1) UNH12
T2H2400
(1) UNH24
(1) UNH09
T2H9800
(1) UNH24
T3H9990
(3) UNH09
(2) UNH09
T3H9920
(1) UNH12
(2) UNH09
T3H9980
(1) UNH24
(2) UNH09
T3H9940
(1) UNH24
(1) UNH09
T3H9220
(2) UNH12
(1) UNH09
T3H9280
(1) UNH12
(1) UNH24
Circuit Designators: 9 = 9000 Btuh 2 = 12000 Btuh 8 = 18000 Btuh 4 = 24000 Btuh (ex. - 8400 consists of one 18000
Btuh compressor and one 24000 Btuh compressor)
Enviromaster International LLC
–––––––––––––––––––––––––––––––––––––––––––––––––
UNH / T2H, T3H, or T4H SySTem CapaCiTieS
Cooling
Btuh (kW)
SEER
36000 (10.5)
13
42000 (12.3)
13
48000 (14.0)
13
35000 (10.2)
13
27200 (8.0)
13
27800 (8.1)
13
29800 (8.7)
13
36400 (10.7)
13
42500 (12.4)
13
31800 (9.3)
13
38500 (11.3)
13
Heating
HSPF
SHR
EER
Btuh (kW)
0.72
12.1
26800 (7.6)
0.68
11.9
32000 (9.4)
0.65
11.8
37400 (11.0)
0.67
11.7
27800 (8.1)
0.74
12.0
20800 (6.1)
0.80
11.9
22200 (6.5)
0.76
11.8
24000 (7.0)
0.76
12.0
28200 (8.3)
0.71
11.8
33400 (9.8)
0.74
11.7
25800 (7.6)
0.73
11.9
30000 (8.8)
Chart continued next page .....
1
uNH-t2H-t3H-t4H
universal air Handler
multi-Zone limited Range Heat Pump
UNH
COP
7.7
3.3
7.7
3.2
7.7
3.2
7.7
3.2
7.7
3.3
7.7
3.3
7.7
3.3
7.7
3.3
7.7
3.2
Top Discharge Condensers
7.7
3.3
7.7
3.3
Rome, New York, USA
Rev. B [10/08]

Advertisement

loading

Summary of Contents for EMI UNH-T2H-T3H-T4H

  • Page 1 28200 (8.3) 0.71 11.8 33400 (9.8) 0.74 11.7 25800 (7.6) 0.73 11.9 30000 (8.8) Chart continued next page ... uNH-t2H-t3H-t4H universal air Handler multi-Zone limited Range Heat Pump Heating HSPF Top Discharge Condensers Rome, New York, USA Rev. B [10/08]...
  • Page 2 EmI ENGINEERING SUbmIttAL UNH-t2H-t3H-t4H (Continued) Model Outdoor Indoor Air Handler T3H9240 (1) UNH09, (1) UNH12, (1) UNH24 T3H2280 (2) UNH12, (1) UNH24 T3H2240 (2) UNH12, (1) UNH24 T3H2220 (3) UNH12 T4H9999 (4) UNH09 T4H9992 (3) UNH09, (1) UNH12 T4H9922 (2) UNH09, (2) UNH12...
  • Page 3: Indoor Unit

    EmI ENGINEERING SUbmIttAL UNH-t2H-t3H-t4H Manufacturer reserves the right to change these specifications at any time without incurring obligation. standard featUres: indoor Unit: • Ceiling-Suspended or Floor Console mounted • Internally Enhanced Copper Tube/Enhanced Aluminum Fin Indoor Coil • Unit-mounted, Infrared compatible control package,...
  • Page 4: Electrical Specifications

    EmI ENGINEERING SUbmIttAL UNH-t2H-t3H-t4H Manufacturer reserves the right to change these specifications at any time without incurring obligation. Indoor Unit V-Ph-Hz 115-1-60 UNH09 UNH12 208/230-1-60 115-1-60 UNH24 208/230-1-60 Power Supply Outdoor V-1-60 Unit Volts T2H8800 208/230 T2H8400 208/230 T2H4400 208/230...
  • Page 5: Indoor Air Flow

    EmI ENGINEERING SUbmIttAL UNH-t2H-t3H-t4H Manufacturer reserves the right to change these specifications at any time without incurring obligation. electrical sPecifications Power Supply Outdoor V-1-60 Unit Volts T3H2240 208/230 T3H2220 208/230 T4H9999 208/230 T4H9992 208/230 T4H9922 208/230 T4H9222 208/230 T4H2222 208/230 Note: * - Control Voltage is supplied from the indoor unit.
  • Page 6: Physical Dimensions

    EmI ENGINEERING SUbmIttAL UNH-t2H-t3H-t4H Manufacturer reserves the right to change these specifications at any time without incurring obligation. indoor Unit ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 11” (279) 26” (660 ) (32) (57) (64) 10 ½” (267) model UNH09/12 UNH24 oUtdoor Unit ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– (1030) ––––––––––––––––––––––– circuit connection locations –––––––––––––––––––––––...

This manual is also suitable for:

T2h8800T2h8400T2h4400T2h2400T2h9800T3h9990 ... Show all