Download Print this page

EMI S2H Specification Sheet

Ductless split system dual-zone heat pump condensing unit

Advertisement

Quick Links

Heat pump
Nominal Capacities:
9,000 and 12,000 Btuh
dEsCrIPtIon
EMI offers the finest high capacity dual zone outdoor
units in the ductless split market, the S2H High Capacity
Condensing Unit. The S2H allows the installation of two
circuits from a single outside location when space or aes-
thetic requirements limit the use of locations. The S2H has
easy access interconnect valves on the back of the unit
and each zone is independent so no mixing of refrigerant
will occur. All 9,000 and 12,000 Btuh units are equipped
with the Duratec Performance package which includes a
large capacity suction accumulator with surge baffles and
enhanced oil management and a factory installed solid
core filter drier.
All EMI products are subject to ongoing develop-
ment programs so design and specifications may
change without notice.
Cabinet -
• Vertically arranged side discharge
CondEnsEr standard FEaturEs
• Scratch and dent resistant injection molded front ac-
cess panel
• Powder coated (2,000 hour salt spray tested) 18 and
20 gauge aluminized steel
• Concealed service valves
• Easy access hose connections at 45° from valve body
Enviromaster International LLC
ductLeSS SpLit SYStem
duaL-Zone Heat pump condenSinG unit
Compressors - Hermetically sealed high efficiency
rotary compressors. Motors are PSC type with inherent
overload protection.
Condenser Fan/Motor - The condenser fan is a large
diameter, high efficiency propeller type, which is directly
connected to the totally enclosed PSC motor. The S2H
units are draw-through airflow design and the PSC motor
is fitted with internal overload protection.
Condenser Coil - Condenser coils are seamless cop-
per tubing arranged in staggered configuration with
enhanced aluminum fins tested to 460psig. The tubes
are mechanically expanded for secure bonding to the
fin shoulder.
Refrigeration Circuits - The S2H is delivered with
pre-charged refrigerant for the condenser coils and
evaporators while charging of field installed piping is
required. Unit refrigeration service valves are solid brass
for sweat connection. Solid core filter driers are factory
installed on all models.
Refrigerant Run Options - The standard system will
support refrigerant runs to the inside unit of 35' of lift,
up to 100' of interconnect.
Reverse Cycle Operation S2H - A four-way reversing
valve, solenoid activated by 24v, is energized for cool-
ing operation. A TXV with internal check valve provides
proven operation through all temperature ranges when
in the heat pump mode.
Controls and Components:
• Compressor and fan motor contactor
• Capacitor
• Low Voltage terminals for evaporator
interconnection
• Large capacity suction accumulators
• Factory installed solid core filter drier
• Heat pump circuits equipped with thermostatically
controlled crankcase heater
• Common suction pressure access point
• Hard Start Assist
sYstEM oPtIons
• Sea Coast Style Coated Coils / Copper-Copper coils
• Wind Baffles -
Louvers•
Web: http://www.enviromaster.com
S2H
P/N# 240006613, Rev. A [06/08]

Advertisement

loading
Need help?

Need help?

Do you have a question about the S2H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EMI S2H

  • Page 1 9,000 and 12,000 Btuh dEsCrIPtIon EMI offers the finest high capacity dual zone outdoor units in the ductless split market, the S2H High Capacity Condensing Unit. The S2H allows the installation of two circuits from a single outside location when space or aes- thetic requirements limit the use of locations.
  • Page 2 All EMI products are subject to ongoing development programs so design and 15” 44” Front of unit ModEL VoLts/HZ/PHasE 9900 208-230/60/1 2200 208-230/60/1 9200 208-230/60/1 (1) Circuit Designators: 9 = 9,000 Btuh • 2 = 12,000 Btuh (ex. - Model 9200 consists of one 9,000 Btuh compressor and one 12,000 Btuh compressor) (2) Always refer to the rating plate for Minimum Circuit Ampacity on all multiple compressor units.
  • Page 3 / WLH sYstEM PErForManCE ModEL Indoor units (Outdoor) 9900 WLH09 + WLH09 2200 WLH12 + WLH12 WLH09 + WLH12 9200 s2H / CaH sYstEM PErForManCE ModEL Indoor units (Outdoor) 9900 CAH12 + CAH12 CAH12 + CAH12 2200 9200 CAH12 + CAH12...
  • Page 4 / unH sIdE dIsCHarGE ModEL Indoor Btuh (Outdoor) units UNH09 + 18,600 9900 UNH09 UNH12 + 22,600 2200 UNH12 UNH09 + 20,600 9200 UNH12 s2Ha High Capacity Condensing unit s2H sYstEM PErForManCE CooLInG sEEr 13.0 12.2 13.0 11.9 13.0 12.0...
  • Page 5 WLC/WLH High Wall Evaporator Side Discharge S2C & S2H Dual Zone Side Discharge Phone: 1-800-228-9364 Fax: 1-800-232-9364 EMI’s HIGH sEEr ProduCt LInE EVaPorators UNC/UNH Universal Evaporator CondEnsErs S1C & S1H Single Zone T2C, T3C & T4C T2H, T3H & T4H 2, 3, &...