Interface Pulse Not Found - Emerson ROSEMOUNT 5300 Reference Manual

Superior performance guided wave radar
Hide thumbs Also See for ROSEMOUNT 5300:
Table of Contents

Advertisement

Rosemount 5300 Series
INTERFACE PULSE NOT
FOUND
Figure 7-6. Echo Curve plot
indicating that the amplitude
threshold for the interface peak
is too high.
7-8
In interface applications where the bottom product has a relatively low
dielectric constant (<40), or if the signal is attenuated in the upper product, the
amplitude of the reflected signal is relatively low and difficult for the transmitter
to detect. In such cases, it may be possible to detect the reflected signal if the
corresponding amplitude threshold is adjusted.
The Rosemount Radar Master (RRM) lets you view a waveform plot to
analyze the measurement signal. The plot shows the signal and the
thresholds used for the different amplitude peaks. By adjusting the Interface
Threshold, it is possible to detect even weak interface signals.
Guidelines for amplitude threshold settings:
The Interface Threshold should be approximately 50% of the interface
signal amplitude.
If possible, the Interface Threshold should be higher than the Surface
Threshold.
You can use the RRM software or a 375 Field Communicator to change the
amplitude thresholds. See "Using the Echo Curve Analyzer" on page 7-10 for
more information.
If the Lower Product Dielectric Constant is known, the corresponding
configuration parameter can be changed as an alternative to adjusting the
amplitude thresholds. See also "Dielectric Constant Settings" on page C-14.
Figure 7-6 illustrates a situation where the Interface Threshold is too high.
The signal amplitude peak at the interface between the upper and lower
products is not detected in this case.
The Interface Threshold is above
the interface peak
3.0
Distance, m
By adjusting the Interface Threshold, the peak at the interface between the
upper and lower products is detected as illustrated in Figure 7-7:
Reference Manual
00809-0100-4530, Rev BA
Interface Threshold
Surface Threshold
Reference Threshold
5.0
July 2009