Download Print this page
Emerson DVS205 Technical Specifications

Emerson DVS205 Technical Specifications

Emerson dual-variable sensor specification sheet

Advertisement

Quick Links

Technical Specifications

DVS205 Dual-Variable Sensor
The DVS205 Dual-Variable Sensor (DVS205)
provides static pressure and differential pressure
inputs to a FloBoss™ 103, FloBoss 107E, or FloBoss
500-Series Flow Manager. The DVS205
communicates via a serial format with the FloBoss.
Variables
Functionally, the DVS205 is a digital transmitter that
measures two flow-related variables simultaneously:
differential pressure and static pressure. These
variables are continuously available to the FloBoss
unit that polls the DVS205.
Transducer and Electronics
The DVS205 contains a transducer and an
electronics circuit. The transducer uses capacitance-
cell technology to sense differential pressure and
piezoresistive technology to sense the static
(absolute or gauge) pressure.
The transducer electronics convert the pressure
variables directly into a digital format, allowing
Remote Automation Solutions
Website: www.EmersonProcess.com/Remote
accurate correction and compensation. A
microprocessor linearizes and corrects the raw
pressure signals (from the sensor) using
characterization data stored in non-volatile memory.
The electronics also allow the DVS205 to
communicate with a FloBoss using a Serial
Peripheral Interface (SPI).
Accuracy
Two versions of the DVS205 are available:
Mounting
The DVS205 is factory installed on a FloBoss™ 103,
FloBoss 107E, or FloBoss 500-Series Flow Manager
to comply with agency requirements. Attached to the
bottom of the sensor body is a Coplanar™ flange.
This flange allows the DVS205 to mount on an
integral orifice assembly or manifold valve.
W8826-A
DVS205 Dual-Variable Sensor
205P with reference accuracy of 0.075% of the
full span.
205E with reference accuracy of 0.10% of the
full span.
Coupling
Sensor Body
Coplanar
Flange
DVS205
April 2011

Advertisement

loading

Summary of Contents for Emerson DVS205

  • Page 1: Technical Specifications

    205E with reference accuracy of 0.10% of the full span. Mounting The DVS205 is factory installed on a FloBoss™ 103, FloBoss 107E, or FloBoss 500-Series Flow Manager to comply with agency requirements. Attached to the bottom of the sensor body is a Coplanar™ flange.
  • Page 2 Technical Specifications DVS205 Multi-Variable Sensor Differential Pressure Input Range 0 to 62.2 kPa (0 to 250" H2O) 0 to 248.8 kPa (0 to 1000" H2O) Reference Accuracy 205E 205P ±0.125% of URL for five years, with up to ±50°F (28°C) ambient temperature changes...
  • Page 3 1.5:1 ratio. To determine the adjusted maximum temperature rating, perform the following calculation: Adjusted max T = Product Max T – 85°C (185°F)) * 1.5] Example: Adjusted Max T = 75°C – [(95°C – 85°C) * 1.5] = 60°C. DVS205 Page 3 – [(Actual Process...
  • Page 4 Page 4 Bristol, Inc., Bristol Canada, BBI SA de CV and Emerson Process Management Ltd, Remote Automation Solutions division (UK), are wholly owned subsidiaries of Emerson Electric Co. doing business as Remote Automation Solutions (“RAS”), a division of Emerson Process Management. FloBoss, ROCLINK, Bristol, Bristol Babcock, ControlWave, TeleFlow and Helicoid are trademarks of RAS.