Summary of Contents for EdgeStar AP10001B

  • Page 1 Portable Air Conditioner AP10001B Owner’s Manual For more information on other great EdgeStar products on the web, go to http://www.edgestar.com...
  • Page 2: Important Safety Information

    Important Safety Information Improper handling can cause serious damage to the appliance and/or to the user. Please read the following safety information. Electrical Safety  This unit is designed for indoor use only.  Do not use the unit in extremely humid or wet environments. ...
  • Page 3: Table Of Contents

    ................... 15 LEANING THE UNIT   ................15 LEANING THE PRE FILTERS   ................15 REPARATION FOR TORAGE   TROUBLESHOOTING ..................16   ................. 17 ROUBLESHOOTING CONTINUED   SPECIFICATIONS ....................18   EDGESTAR LIMITED WARRANTY ..............19 EdgeStar Portable Air Conditioner...
  • Page 4: Introduction

    Introduction Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship.
  • Page 5: Parts Identification

    Louver Exhaust Hose Handle Remote Sensor Note: You must open the front air Caster vent when operating the unit. Back View Pre-filter Air Intake Exhaust Outlet Upper Drain Valve Air Intake/ Compressor pre-filter Lower Drain Valve EdgeStar Portable Air Conditioner...
  • Page 6: Installing The Carbon Filter

    Installing the Carbon Filter Your EdgeStar portable air conditioner ships with a pre-filter and an activated carbon filter. The carbon filter will help remove contaminates and odors from the air. It is recommended you replace the carbon filter every two to three months, or as needed. It is necessary to clean the pre-filter periodically.
  • Page 7: Window Kit Installation Instructions

    Your window kit can be installed on a horizontal or vertical sliding window as shown in the following pictures: Follow the instructions on the next pages to install the window kit. EdgeStar Portable Air Conditioner...
  • Page 8: Installing The Window Plates

    Installing the window plates  1. Open your window and place the window kit with grooved side facing outward on the window sill. Then, slide the window kit plate to fit the width of the window. You can use screws to secure the window kit plate from sliding. ...
  • Page 9: Attaching The Oval Adapter To The Exhaust Hose

      4. Roll the unit towards the window kit. Leave a space that is at least 20 inches to the wall. EdgeStar Portable Air Conditioner...
  • Page 10: Connecting The Exhaust Hose To The Unit

    Connecting the exhaust hose to the unit  5. Align the slots on the hose connector to the tabs and snap into the back of the unit. Connecting the oval adapter to the window kit  6. Push the oval adapter through the window kit hole until it snaps in place.
  • Page 11: Notes About The Exhaust Hose

    B: You must remove the exhaust hose if the unit is in Fan Mode or Dehumidify mode. Note: the exhaust hose may be compressed or extended according to your installation requirements; however, it is recommended to keep the exhaust hose length at a minimum. EdgeStar Portable Air Conditioner...
  • Page 12: Draining The Unit

    Draining the Unit The unit will need to be drained if set to dehumidify mode. When the portable air conditioner is in cooling mode, it will remove moisture from the air. The condensed water from the air will be collected in an internal reservoir and will be evaporated and exhausted out of the exhaust hose.
  • Page 13: Control Panel Overview

    Decreases the set temperature or time when the Timer button is enabled. Indicator Function LED Display The LED can display the ambient temperature in Fan and Dehumidify Mode, set temperature in Cool Mode, and the number of hours when setting the timer. EdgeStar Portable Air Conditioner...
  • Page 14: Operating The Control Panel

    Operating the Control Panel Use the Power button to turn the portable air conditioner on and off. Power Auto-Restart: If power to the unit is interrupted, the air conditioner will restart itself in its last used mode/settings once power is restored. The compressor will restart after 3 minutes.
  • Page 15: Fan Button

    2 degrees after an additional 30 minutes and maintain this temperature for 7 hours before it returns to the original temperature and ends the Sleep mode. The Sleep mode is not available in Dehumidify and Fan Only modes. EdgeStar Portable Air Conditioner...
  • Page 16: Using The Remote Control

    Using the Remote Control The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The functions on the remote are the same as on the control panel. NOTES: Be careful not drop Up Button the remote control.
  • Page 17: Normal Sounds

    Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning. Follow the instructions on the next page to clean the portable air conditioner. EdgeStar Portable Air Conditioner...
  • Page 18: Cleaning The Unit

    2-3 needed. Allow the pre-filter to air dry in a cool and shaded place. months or as needed. Contact Dry thoroughly before reinstalling. EdgeStar retailers for replacement filters. Warning: Never operate the unit without the filters. Preparation for Storage...
  • Page 19: Troubleshooting

    The control panel Unit may have a faulty Contact customer lights blink randomly control panel service EdgeStar Portable Air Conditioner...
  • Page 20: Troubleshooting Continued

    Troubleshooting continued Issue Possible Cause Solution My air conditioner is Unit is not operating in Set the unit to be in not cooling at all cooling mode cooling mode, and lower the set temperature (pg. 11) The compressor is not The compressor may take up to 3 minutes to turn on, or longer if it is...
  • Page 21: Specifications

    Description of product: Portable Air Conditioner AP10001B Model: Voltage/Frequency: AC 115V~60Hz Input Power: 1125W Current: 10.1A Color: Black and Gray Coolant: R410A Timer: 24 Hour Dimensions 16 ¾” x 26 ½” x 13 ½” WxHxD: Weight: 66 lbs EdgeStar Portable Air Conditioner...
  • Page 22: Edgestar Limited Warranty

    EdgeStar authorized repair facility. PARTS: For a period of ONE (1) YEAR from the date of original purchase, EdgeStar will supply new, rebuilt, or refurbished parts free of charge. EdgeStar may request a defective part be returned in exchange for the replacement part.
  • Page 23 Register your product, download owner’s manuals, access additional troubleshooting resources, and obtain more information on other great EdgeStar products on the web at: http://www.edgestar.com Product contents and specifications may change without notice. Copyright © 2010 Living Direct, Inc. All rights reserved.

Table of Contents