Portable Air Conditioner AP10001B Owner’s Manual For more information on other great EdgeStar products on the web, go to http://www.edgestar.com...
Important Safety Information Improper handling can cause serious damage to the appliance and/or to the user. Please read the following safety information. Electrical Safety This unit is designed for indoor use only. Do not use the unit in extremely humid or wet environments. ...
................... 15 LEANING THE UNIT ................15 LEANING THE PRE FILTERS ................15 REPARATION FOR TORAGE TROUBLESHOOTING ..................16 ................. 17 ROUBLESHOOTING CONTINUED SPECIFICATIONS ....................18 EDGESTAR LIMITED WARRANTY ..............19 EdgeStar Portable Air Conditioner...
Introduction Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship.
Louver Exhaust Hose Handle Remote Sensor Note: You must open the front air Caster vent when operating the unit. Back View Pre-filter Air Intake Exhaust Outlet Upper Drain Valve Air Intake/ Compressor pre-filter Lower Drain Valve EdgeStar Portable Air Conditioner...
Installing the Carbon Filter Your EdgeStar portable air conditioner ships with a pre-filter and an activated carbon filter. The carbon filter will help remove contaminates and odors from the air. It is recommended you replace the carbon filter every two to three months, or as needed. It is necessary to clean the pre-filter periodically.
Your window kit can be installed on a horizontal or vertical sliding window as shown in the following pictures: Follow the instructions on the next pages to install the window kit. EdgeStar Portable Air Conditioner...
Installing the window plates 1. Open your window and place the window kit with grooved side facing outward on the window sill. Then, slide the window kit plate to fit the width of the window. You can use screws to secure the window kit plate from sliding. ...
Connecting the exhaust hose to the unit 5. Align the slots on the hose connector to the tabs and snap into the back of the unit. Connecting the oval adapter to the window kit 6. Push the oval adapter through the window kit hole until it snaps in place.
B: You must remove the exhaust hose if the unit is in Fan Mode or Dehumidify mode. Note: the exhaust hose may be compressed or extended according to your installation requirements; however, it is recommended to keep the exhaust hose length at a minimum. EdgeStar Portable Air Conditioner...
Draining the Unit The unit will need to be drained if set to dehumidify mode. When the portable air conditioner is in cooling mode, it will remove moisture from the air. The condensed water from the air will be collected in an internal reservoir and will be evaporated and exhausted out of the exhaust hose.
Decreases the set temperature or time when the Timer button is enabled. Indicator Function LED Display The LED can display the ambient temperature in Fan and Dehumidify Mode, set temperature in Cool Mode, and the number of hours when setting the timer. EdgeStar Portable Air Conditioner...
Operating the Control Panel Use the Power button to turn the portable air conditioner on and off. Power Auto-Restart: If power to the unit is interrupted, the air conditioner will restart itself in its last used mode/settings once power is restored. The compressor will restart after 3 minutes.
2 degrees after an additional 30 minutes and maintain this temperature for 7 hours before it returns to the original temperature and ends the Sleep mode. The Sleep mode is not available in Dehumidify and Fan Only modes. EdgeStar Portable Air Conditioner...
Using the Remote Control The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The functions on the remote are the same as on the control panel. NOTES: Be careful not drop Up Button the remote control.
Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning. Follow the instructions on the next page to clean the portable air conditioner. EdgeStar Portable Air Conditioner...
2-3 needed. Allow the pre-filter to air dry in a cool and shaded place. months or as needed. Contact Dry thoroughly before reinstalling. EdgeStar retailers for replacement filters. Warning: Never operate the unit without the filters. Preparation for Storage...
Troubleshooting continued Issue Possible Cause Solution My air conditioner is Unit is not operating in Set the unit to be in not cooling at all cooling mode cooling mode, and lower the set temperature (pg. 11) The compressor is not The compressor may take up to 3 minutes to turn on, or longer if it is...
EdgeStar authorized repair facility. PARTS: For a period of ONE (1) YEAR from the date of original purchase, EdgeStar will supply new, rebuilt, or refurbished parts free of charge. EdgeStar may request a defective part be returned in exchange for the replacement part.