Output Signal Description
Pin 1 (+22V)
This pin can supply +22VDC to supply power for
user automation controls. It is limited to 250mA.
Pin 2 (Gnd)
Pin 2 is the 22VDC and Status Out return. It is tied
to the chassis ground.
Pin 3 (Gnd)
Pin 3 is the 22VDC and Status Out return. It is tied
to the chassis ground.
Pin 4 (Status Driver)
An active low output on pin 4 indicates the condition
set on Jumper Block SH702 has occurred (see Fig-
ures 4-7 and 4-8). The factory default is OVERLOAD.
Pin 5 (Not Used)
Pin 5 is reserved for future use.
Pin 6 (U/S Active)
An active low output on pin 6 indicates the ultra-
sound is being delivered to the probe.
Pin 7 (System Fault)
An active low output on pin 7 indicates the generator
has detected an out of tolerance voltage fluctuation.
The front panel status display will indicate FAULT.
Pin 8 (OVERTEMP)
An active low output on pin 8 indicates that one of
the power modules in the generator has overheated
and automatically shut down. The front panel status
display will indicate OVERTEMP.
Pin 9 (OVERLOAD)
An active low output on pin 9 indicates that exces-
sive power beyond the generators rated output is be-
ing drawn. The ultrasonic signal is shut down when
an overload condition is detected. The front panel
status display will indicate OVERLOAD. The over-
load signal resets when the operate input deactivates
or the TEST switch is released.
Dukane Manual Part No. 403–566–01
Section 5 – Rear Connectors
NOTE
Active Low outputs are open collector
Darlington transistors that sink current to
ground (either chassis ground or isolated com-
mon @20mA maximum).
Custom automation users must supply their own
pullups. See Appendix C for sample circuits.