Download Print this page

Dukane AN200 Application Note page 8

Automation interface requirements for the system input interface of a dpc ii / ii+ welding system

Advertisement

DUKANE
Intelligent Assembly Solutions
DPC II / II+ System Input Interface Example:
(DPC II / II+ configured to accommodate an NPN type PLC output card that sinks the DPC inputs).
Output Device
PLC
PIN NUMBER
Note: This diagram provides a simplified representation of the DPC II / II+ input device for the purpose
of demonstrating circuit functionality.
© Dukane Corporation 2003. All rights reserved.
- 8 -
200-1203 Cable
3
ISOLATED OPERATE INPUT
5
ISOLATED PRESS CONTROL
9
ISOLATED AUTOMATION STOP/END OF WELD
Dukane Corporation
2900 Dukane Drive Saint Charles, IL 60174 USA
Phone (630) 797-4900 FAX (630) 797-4949
http://www.dukane.com/us
A
p
p
l
i
c
A
p
p
l
i
c
+22 VDC
1
4
2
J701
PIN DESCRIPTION
a
t
i
o
n
N
o
a
t
i
o
n
N
o
AN200
DPC II / II+
JU724 (Factory Default)
JU726
JU725
Bi-directional
Input Device
t
e
t
e
Rev 01