Jumper Selections

Carefully separate the top and bottom halves of the main unit case. Once the cover is removed, the polarity
jumpers will be visible next to the parking light, dome light, and Auxiliary 1 relays. Set the jumpers for the
correct polarity output as described below, then reassembly the main unit case.
Parking Light Output. Selects the polarity (+/-) for the output of the on-board Parking Light relay.
Left Pin + Center Pin = positive
Right Pin + Center Pin = negative
Dome Light Output. Selects the polarity (+/-) for the output of the on-board Illuminated Entry relay.
Left Pin + Center Pin = negative
Right Pin + Center Pin = positive
Auxiliary 1 Output. Selects the polarity (+/-) for the output of the on-board Aux 1 relay.
Left Pin + Center Pin = positive
Right Pin + Center Pin = negative
Auxiliary 1
Relay
Jumper S S ettings
Dome Light
Relay
default settings shown
Parking Light
Relay
Lock Relay