2.7.2

Shuttle-drive housing

4
12
1
2
3
Regulation and inspection
The shuttle-drive housing 4 is factory-aligned.
It may only be altered in exceptional circumstances.
With the shuttle-drive housing correctly aligned there must be a
distance of 0.4 mm between the shuttle and the adjusting ring
(see section 2.7.1).
The distance between the slide-plate surface and the thread-drawing
plate 3 is 3.8 mm.
Caution: danger of injury
Turn off the main switch.
The shuttle-drive housing 4 may only be adjusted with the sewing
machine switched off.
Adjustment
Remove the shaping module and slide plate (see section 2.6).
Unscrew locking screw 5.
Beneath the locking screw there is a stop screw.
Adjust stop screw.
The distance between the slide-plate surface and the
thread-drawing plate 3 is 3.8 mm
The distance is checked with gauge 1.
Retighten locking screw 5.
Undo screws 2 of the shuttle-drive housing.
Move shuttle-drive housing 4.
There must be a distance of 0.4 mm between the shuttle and the
adjusting ring (see section 2.7.1).
Retighten screws 2 of the shuttle-drive housing.
5
Check the distance of the shuttle beak to the needle and adjust if
necessary (see section 2.7.1).