10
8
1
9
–
Place gauge 1 on the base plate.
–
Unscrew safety shutter and head cover.
–
Undo clamping screw 9.
–
Lock the sewing machine in position E.
–
Lower the needle bar 8 onto the gauge 1.
The pin of gauge 1 must fully penetrate the needle bar.
–
Tighten needle-bar attachment screw 10.
The needle-attachment screw 10 must be aligned in parallel to the
10
arm shaft and point to the rear (towards the handwheel).
–
Replace all the parts which have been removed.
IMPORTANT !
When fitting the thread clipper place both shims between the
thread clipper and slide plate.