10
12
9
8
7
Adjustment:
Fold the upper part of the machine aside.
Undo locking screws 6.
Undo locking screws 8 on adjustment ring 9.
Extract driver with driver shaft 7 forwards from the shuttle-track
support 10.
Once the driver shaft 7 has been dismantled, remove or add
shims 12. The shims can be found in the accessory kit.
Hint
The use of a smaller needle normally requires a shim to be added
and vice versa.
Replace driver with driver shaft 7 in the shuttle-track support 10
and push it back as far as it will go.
Push adjustment ring 8 as far as it will go against the end of the
shuttle-track support 10.
Fully tighten locking screws 8.
This prevents the driver from being axially shifted.
Reset the loop stroke (see chapter 3.5).
Check the setting by turning the belt pulley on the arm shaft. The
right-hand side of the needle must be parallel to the driver and at a
very small distance from it.
If the setting is not correct the adjustment process must be
repeated.
CAUTION:
After adjusting the driver/needle distance it is essential to readjust the
loop stroke as described in chapter 3.5.