8
4
–
Turn the handwheel in the direction of rotation until the shuttle tip
extends 2 mm beyond the right-hand side of the needle.
CAUTION:
Care must be taken that the driver touches the shuttle in the
direction of rotation.
–
Undo locking screws 4.
–
Adjust the height of the needle bar so that the lower edge of the
shuttle tip just becomes visible in the eye of the needle.
–
Fully tighten locking screws 4.
–
Refasten clamp 3 with screws 2.
2 mm