8
4
Turn the handwheel in the direction of rotation until the shuttle tip
extends 2 mm beyond the right-hand side of the needle.
CAUTION:
Care must be taken that the driver touches the shuttle in the
direction of rotation.
Undo locking screws 4.
Adjust the height of the needle bar so that the lower edge of the
shuttle tip just becomes visible in the eye of the needle.
Fully tighten locking screws 4.
Refasten clamp 3 with screws 2.
2 mm