DISASSEMBLY, ASSEMBLY, AND ADJUSTMENT
Carriage guide shaft (left)
Carriage guide shaft (right):
Per
form the above adjustment at the 10th and 70th column positions, and at the middle of the platen. When
gaps at all three positions match, the adjustment is complete.
the
4-24
Figure 4-36. Carriage Guide Shaft Lever Movement
Turned clockwise - The platen gap widens.
Turned counterclockwise - The platen gap narrows.
Turned clockwise - The platen gap narrows.
Turned counterclockwise - The platen gap widens.
Figure 4-37. Platen Gap Adjustment Positions