Solution Pump Replacement - Century 400 CEXT7 Operating Instructions Manual

Table of Contents

Advertisement

MAINTENANCE
!
WARNING:

SOLUTION PUMP REPLACEMENT

1. Turn off all switches and unplug the machine.
2. Remove recovery tank.
3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the
inside of the frame.
4. Remove solution hoses from fittings in pump.
5. Remove the (2) screws that fasten the pump to the frame.
6. Reverse process to install pump.
PUMP REPLACEMENT KITS SHURFLO 86026410 - PRV NO. (65257)
Pump Head
Replacement
86251050
PRV NO. 65188
4-5
ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM
THE FOLLOWING REPAIRS.
Valve Asm
86258840
PRV NO. 84162
86037910 CEXT7 03/23/07
Diaphragm
86235110
PRV NO. 29207

Advertisement