CDA HCE340 Manual For Installation, Use And Maintenance page 19

Domino two plate electric hob
Table of Contents

Advertisement

A
Fig. 8.1
Fig. 8.2
230 V
L
N
1
PE
Fig. 8.3
230 V
L
Fig. 8.4
38
REPAIRS
REPLACING THE POWER SUPPLY CABLE
(for 2 electrical plates and vitroceramic models)
Turn the cooktop over and unhook the terminal board cover by inserting a screwdriver
into the two hooks "A" (fig. 8.1).
Open the cable gland by unscrewing screw "F" (fig. 8.2), unscrew the terminal screws
and remove the cable.
The new supply cable, of suitable type and section, is connected to the terminal board
following the diagram fig. 8.3.
REPLACING THE POWER SUPPLY CABLE (for gas models)
- The supply cable must be replaced with a cable of the same type.
- The electrical cable must be connected to the terminal board following the diagrams of
fig. 8.4.
F
FEEDER CABLE SECTION
COOKING HOB GAS
type "H05V2V2-F"
resistance to temperatures of 90°C
230 V~
COOKING HOB ELECTRIC HOTPLATES
The external diameter of the supply cable must not be more than 9 mm.
tipo "H05RR-F"
230 V~
(L )
2
COOKING HOB VITROCERAMIC
The external diameter of the supply cable must not be more than 9 mm.
type "H05RR-F"
230 V~
N
2
3 x 0,75 mm
2
3 x 1,50 mm
2
3 x 1,50 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcc360

Table of Contents