Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury, death
and/or property damage! Retain instructions for future reference.
BUILT TO LAST
for the nailer. Use fil-
Table Of Contents
tered, lubricated, regu-
General Safety . . . . . . . . . . . . . .1-2
lated compressed air
Specifications . . . . . . . . . . . . . . . .2
only. Use of a com-
Contact Trip Safety Mechanism . .3
pressed gas instead of
Operating The Nailer . . . . . . . . .3-5
compressed air may
cause the nailer to explode which
Troubleshooting . . . . . . . . . . . . . .6
will cause death or serious personal
Warranty . . . . . . . . . . . . . . . . . . . .7
injury.
Do not exceed maxi-
Description
mum operating pres-
This nailer is designed for roofing
sure of the nailer (115
(asphalt and fiberglass shingles), reroof-
psi). The nailer will
ing, and sheathing installation.
not function properly.
Features include: convenient top load-
Do not use a com-
ing magazine which holds up to 120
pressed air source capable of more
nails, an adjustable shingle guide, a
than 200 psi. The nailer could
rubber handle grip, and an adjustable
explode which will cause death or
depth of drive mechanism.
serious personal injury.
Never use gasoline or
General Safety Information
other flammable liq-
This manual contains safety, opera-
uids to clean the nail-
tional and maintenance information.
er. Never use the nail-
er in the presence of
Read this manual and
flammable liquids or gases. Vapors
understand all safety warn-
could ignite by a spark and cause an
ings and instructions
explosion which will result in death
before operating the nail-
MANUAL
or serious personal injury.
er. Contact your Campbell
Hausfeld representative if
Always remain in a
you have any questions.
firmly balanced
position when
OPERATOR'S RESPONSIBILITY:
using or handling
Before operating the nailer, read and
the nailer.
understand all safety warnings and
labels. Follow the operating instruc-
Do not modify or
tions outlined in this manual.
disable the Work
Contact Element
EMPLOYER'S RESPONSIBILITY:
(WCE). Do not tie
Distribute this instruction manual to all
or tape the WCE or
users before allowing use of the nailer.
trigger in a
Ensure all operators read, understand
depressed position. Death or serious
and follow all safety warnings, labels
personal injury could result.
and instructions outlined in this
Do not touch the
manual.
trigger unless dri-
ving nails. Never
Danger indicates
an imminently
attach air line to
hazardous situation which, if not
nailer or carry nail-
avoided, WILL result in death or seri-
er while touching
ous injury.
the trigger. The
Do not use any type of flammable
tool could eject a fastener which will
gases or oxygen as a power source
result in death or serious personal
injury.
Campbell Hausfeld Nailers meet or exceed Industries' Standards as set forth by the American National
Standard Institute/International Staple, Nail and Tool Association in ANSI/ISANTA SNT-101-1993.
© 1998 Campbell Hausfeld
Model RN1545
Coil Roofing
Nailer
TM
Model RN1545
O
CO
2
Locate model and serial number on
tool magazine and cap and record
below:
Model No. ________________________
Serial No. _________________________
Retain these numbers for
future reference.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Always
disconnect
nailer from
air line
before
clearing jams, adjusting or servicing
the nailer, relocating the nailer, or
when the nailer is not in use.
Always reconnect the air line
BEFORE loading any fasteners. The
nailer could eject a fastener causing
death or serious personal injury.
Protect your eyes and
ears. Wear Z87 safety
glasses, with side
shields. Wear hearing
protection. Employers
and users are responsible for ensur-
ing the user or anyone near the
nailer wears this safety protection.
Serious eye injury or permanent
hearing loss could result.
IN264200AV 4/98

Advertisement

loading
Need help?

Need help?

Do you have a question about the RN1545 and is the answer not in the manual?

Questions and answers

Summary of Contents for Campbell Hausfeld RN1545

  • Page 1 Serious eye injury or permanent injury. hearing loss could result. IN264200AV 4/98 Campbell Hausfeld Nailers meet or exceed Industries’ Standards as set forth by the American National Standard Institute/International Staple, Nail and Tool Association in ANSI/ISANTA SNT-101-1993. © 1998 Campbell Hausfeld 8-Sp...
  • Page 3: Guía De Diagnóstico De Averías

    Modelo RN1545 Model RN1545 Manual de Instrucciones Operating Instructions Operating The Nailer CONTACT TRIP SAFETY MECHANISM RECOMMENDED HOOKUP Guía de Diagnóstico de Averías The RN1545 Coil Roofing Nailer is The illustration below shows the Read this manual and understand equipped with a contact trip safety Deje de usar la clavadora inmediatamente si alguno de los si guientes problemas ocurre.
  • Page 8 IN264200AV 4/98 Las clavadoras de Campbell Hausfeld Nailers cumplen o exceden los estándards de la Industria establecidos en los códigos SNT-101-1993 de las organizaciones norteamericanas ANSI/ISANTA . © 1998 Campbell Hausfeld.
  • Page 9 à l’ouïe. mortelles. IN264200AV 4/98 Les Cloueuses Campbell Hausfeld conforment aux/ou dépassent les standards de l’American National Standard/International Staple, Nail and Tool Association in ANSI/ISANTA SNT-101-1993. © 1998 Campbell Hausfeld 8-Fr...
  • Page 11: Guide De Dépannage

    Instructions D’Utilisation Modèle RN1545 Modèle RN1545 Instructions D’Utilisation MÉCANISME DE SÛRETÉ À Utilisation de la Cloueuse BRANCHEMENT RECOMMANDÉ Guide De Dépannage DÉCLENCHEMENT PAR CONTACT Le branchement recommandé est illus- Lire attentivement ce manuel afin La cloueuse RN1545 est équipée d’un tré...
  • Page 12: Mécanisme De Déclenchement- Par Contact (Wce)

    L’opération de déchargement s’ef- Les clous pour finition Campbell Hausfeld sont disponibles aux magasins dans votre quartier. Pour de l’assistance, com- ment par contact (WCE) sur la sur- fectue à l’inverse de l’opération de poser le 1-800-543-6400.