MSW2-3: Buffering
[Outline]
Select buffering print enable/disable.
ON (1) OPERATION: Buffering print is enabled.
OFF (0) OPERATION: Buffering print is disabled.
[Default]
OFF (0) [Valid]
MSW2-4: Full Columns print
[Outline]
Select the processing if print data closes to the end of line or the right of print width.
ON (1) OPERATION:
OFF (0) OPERATION:
<Example>
[Default]
OFF (0) [Line Feed]
MSW2-5: Cover close return
[Outline]
Select the operating taken after printer cover is opened during printing, paper is refilled with
no-paper (PE) is detected, then cover is closed to restart printing.
ON (1) OPERATION:
OFF (0) OPERATION:
[Default]
OFF (0) [Next]
Spool Print
・ Save a certain amount of print buffer to internal RAM for collective printing.
・ If cut command is entered, print starts even before the specified amount is reached.
・ If no cut command is entered and the entered data does not reach the specified
amount, data entered to print buffer is not printed.
Full Col print
If printer receives data/command exceeding the full column, printer further waits for
print data.
If data exceeding the full column is a command, printer operates
following the command.
If printer receives data/command exceeding the full column, it automatically prints
data in buffer followed by a line-feed.
If the first data after exceeding the full column is a control code such as<ESC !>;
If OFF (0) is set, print data within buffer and put a line feed, or
If ON (1) is set, print no data within buffer and further wait for print data.
Resume aft PE
Restart printing from the heading of remaining data.
During printing image, bar code, vertically-doubled character or page mode, if cover
open or PE is detected, then after return, restart printing from heading of the
remaining data.
Print data continued from the previous printing. During printing, if cover open or PE
is detected, then after return, restart printing data immediately after an error data.
OFF (0)
Invalid
OFF (0)
Line Feed
OFF (0)
Next
- 181 -
ON (1)
Valid
ON (1)
Wait Data
ON (1)
Top