ESC c5 n
[Function]
Enabling/Disabling Panel Switches
<1B>H<63>H<35>H<n>
[Code]
[Range]
{0 =< n =< FF} Data is described in Hex code.
Selecting the LF switch valid/invalid.
[Outline]
• "n" is valid only in the lowest bit (n0).
• "n" bit means the followings.
[Caution]
When the panel switch is disabled with this command, the LF switch is disabled. Therefore,
the paper cannot be fed by operating the LF switch.
• The initial value of n is "0".
[Default]
[Sample Program]
LPRINT CHR$ (&H1B) + "c5" + CHR$ (0); .........When enabling the LF switch
LPRINT CHR$ (&H1B) + "c5" + CHR$ (1); ......... When disabling the LF switch
n0
0
1
LFSW invalid.
Condition
LFSW valid.