Zanussi ZWG 5120 P User Manual page 22

Hide thumbs Also See for ZWG 5120 P:
Table of Contents

Advertisement

Fault code and malfunction
Hoofdwas
Lavage
Extra spoelen
Rinçage plus
Einde
Fin
The light of button 6 flashes
and the light 7.1 illuminates:
Problem with the water supply
Hoofdwas
Lavage
Extra spoelen
Rinçage plus
Einde
Fin
The light of button 6 flashes
and the light 7.2 illuminates:
Problem with the water drain-
age
Hoofdwas
Lavage
Extra spoelen
Rinçage plus
Einde
Fin
The light of button 6 flashes
and the light 7.3 illuminates:
Door open
22
The water tap is closed.
• Open the water tap.
The inlet hose is squashed or kinked.
• Check the inlet hose connection.
The filter in the inlet hose or the inlet valve filter are blocked.
• Clean the water inlet filters (read "Cleaning the water inlet filters" for more details).
The drain hose is squashed or kinked.
• Check the drain hose connection.
The drain filter is clogged.
If the appliance stops working without discharging the water , first carry out an
emergency drain:
• turn the programme selector dial to
• unplug the appliance;
• close the water tap;
• if necessary, wait until the water has cooled down;
• unscrew the drain hose from the rear support (see "Frost precaution") and un-
hook it from the sink or spigot;
• let it run along the floor;
• place a bowl on the floor and place the end of the draining hose into the bowl.
The water should drain by gravity into the bowl. When the bowl is full, empty
it. Repeat the procedure until water stops flowing out ;
• screw the draining hose to the rear support and reposition it;
• open the door and remove the laundry;
• carry out the drain filter cleaning as described in "Cleaning the drain filter";
• at the end of cleaning action, close the door and insert the mains plug again;
• run a drain programme to check if the appliance works now.
The door has not been closed or is not closed properly.
• Close firmly the door.
Possible cause / Solution
;