CHAPTER 5

II. TROUBLESHOOTING

Causes and corrective actions for possible image defects and malfunctions during operation
are described below.
A. Troubleshooting Image Defects
1. Image not output
Cause 1
: Faulty connection of the parallel cable/USB cable
Corrective action : Securely connect the parallel cable/USB cable.
Cause 2
: Faulty contact image sensor
Corrective action : Replace the contact image sensor.
Cause 3
: Faulty main PCB
Corrective action : Replace the main PCB.
2. Uneven image density or lines
Cause 1
: Dirt on the document cover or document glass
Corrective action : Clean the document cover or document glass.
Cause 2
: Faulty calibration data
Corrective action : Perform the calibration.
Cause 3
: External light is entering into the scanner. External light entering into
the contact image sensor can cause uneven image density.
Corrective action : Fully close the document cover. If it is impossible, cover with a sheet
etc. to prevent external light.
Cause 4
: Faulty contact image sensor
Corrective action : Replace the contact image sensor.
Cause 5
: Faulty main PCB
Corrective action : Replace the main PCB.
5 - 2