Broan Elite E64000 SERIES Installation Instructions Manual

Broan Elite E64000 SERIES Installation Instructions Manual

Hide thumbs Also See for Elite E64000 SERIES:

Advertisement

INSTALLATION INSTRUCTIONS
HB0072
E64000 SERIES
INTENDED FOR DOMESTIC COOKING ONLY
!
!
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14.
Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711
Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119
REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register
SV08341 rev. B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Elite E64000 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Broan Elite E64000 SERIES

  • Page 1 READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14. Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119 REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register SV08341 rev. B...
  • Page 2: To Reduce The Risk Of Fire, Electric Shock Or Injury To Persons, Observe The Following

    Broan Elite E64E Series hood must be installed for the size of the surface element. with one Broan exterior blower model 331H, 332H, 335 or 336; or one Broan in-line blower models HLB3, HLB6, HLB9, HLB11. Other blowers cannot be substituted. (Exterior or in-line blowers are sold separately.)
  • Page 3: Range Hood System

    E64000 SERIES RANGE HOOD SYSTEM - INTERNAL BLOWERS ODEL (10” R OUND ODEL (7” R ODEL OUND ODEL ODEL APACITY (8” R OUND ODEL 7” R 8” R OUND OUND ODEL DJUSTABLE LBOW DJUSTABLE LBOW (10” R OUND DJUSTABLE LBOW ODEL 8”...
  • Page 4 E64000 SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLOWERS ODEL HLB9 (800 ODEL APACITY HLB11 (1100 335 (1200 ODEL LINE LOWER 331H (600 336 (1500 ODEL 8” 12” INCLUDES TWO 332H (900 XTERIOR LOWER 10’’ ROUND TRANSITIONS XTERIOR LOWER ODEL (10”...
  • Page 5 The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blowers (included with the hood), or hood using external blowers. For hood using external blowers, the Broan Elite E64000 Series must be installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only.
  • Page 6: Prepare The Installation

    2. PREPARE THE INSTALLATION CAUTION When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves. Make sure that the following items are included: - Range hood - Accessories: • Baffle filters • Baffle filters handles (located inside the hood) •...
  • Page 7: Install Backsplash (Optional)

    2. PREPARE THE INSTALLATION (CONT’D) UCTED INSTALLATIONS ONLY Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below. NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the discharge chosen (vertical or horizontal).
  • Page 8: Remove The Adapter

    4. REMOVE FILTERS AND GREASE DRIP RAIL A. Remove tape on filters. Remove filters from hood and set aside. NOTE: It is recommended to start with the center one(s). B. Remove tape on grease drip rail (1). Lift out grease drip rail and set aside.
  • Page 9: Horizontal Discharge Installation

    6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY) Remove the knockout for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below. ERTICAL DISCHARGE ORIZONTAL DISCHARGE NOTE: For ducted installation only. HR0021 Punch out the appropriate electrical knockout hole on top (A) or back (B) of the hood.
  • Page 10 7. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) ONLY) Slide the blower to disengage its flange from the retaining bracket. HD0270 Flip the blower and engage its flange in the back wall retaining bracket. IGHT Using a 5/16” socket and the OUNTING screws previously removed, secure CREW...
  • Page 11: Install The Hood

    10. INSTALL THE HOOD (ALL BLOWERS) INTERNAL BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of the screws (smaller part of the key holes [A]) with a pen. Remove the hood and install the (4) 1/2” double thread screws at marked positions, leaving a 1/8”...
  • Page 12: Install Light Bulbs

    13. INSTALL LIGHT BULBS WARNING In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed fixtures. This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (not included). 1.
  • Page 13: Operation

    15. USE AND CARE Baffle Filters The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe. Allow filters to dry completely before reinstalling them in the hood.
  • Page 14: Warranty

    BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Page 15: Wiring Diagrams

    18. WIRING DIAGRAMS Broan Elite E64000 Series NEON Internal blower hoods SPEED SWITCH CONTROL On 3 Off 2 USE ONLY WITH APPROPRIATE MAKE-UP AIR SYSTEM THERMOSTAT LINE NEUTRAL GROUND LAMP SWITCH COLOR CODE BLACK BLUE BROWN ORANGE WHITE LAMP LAMP...
  • Page 16: Service Parts

    19. SERVICE PARTS Broan Elite E64000 Series Broan Elite E64000 Series Internal blower hoods Exterior or In-Line blower hoods 9 10 HL0104 HL0103 . (H . (H OOD WIDTH OOD WIDTH ESCRIPTION ART NO ESCRIPTION 30” 36” 42” 48” 30” 36” 42” 48”...

Table of Contents