Temperature checkout

Proper cooling of the system is important for proper operation and system
reliability. For a typical IBM xSeries server, you should make sure:
v Each of the drive bays has either a drive or a filler panel installed
v The cover is in place during normal operation
v There is at least 50 mm (2 inches) of ventilated space at the sides of the server
v The cover is removed for no longer than 30 minutes while the server is
v A removed hot-swap drive is replaced within two minutes of removal
v Cables for optional adapters are routed according to the instructions provided
v The fans are operating correctly and the air flow is good
v A failed fan is replaced within 48 hours
In addition, ensure that the environmental specifications for the system are met.
See "Features and specifications" on page 4.
20
Hardware Maintenance Manual: xSeries 220 Type 8645
c. Use your thumb and index finger to pull the battery from under the battery
clip.
d. Ensure that the battery clip is touching the base of the battery socket by
pressing gently on the clip.
a. Tilt the battery so that you can insert it into the socket, under the battery
clip.
b. As you slide it under the battery clip, press the battery down into the
socket.
parameters.
v Set the system date and time.
v Set the power-on password.
v Reconfigure your server.
and 100 mm (4 inches) at the rear of the server
operating
with the adapters (ensure that cables are not restricting air flow)