Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32494
Braun Corporation FMVSS No. 403
Quick Reference Installation Sheet 32494
"DOT — Private Use Lift"
NHTSA Vehicle Physical Requirements
OEM (Van) Chassis
Floor Requirements
Nonmodified OEM full
size floors meet all
requirements.
Alternative floor
structures are allowed
providing the installed lift
system passes all FM-
VSS 403 requirements.
Figure A
Door Opening Dimensions
Vehicle lift access door opening
must meet specified dimensions.
A
Minimum Clear Door
Opening Height
B
Clear Door Opening Width
C
Maximum Floor-to-Ground
"DOT - Private Use Lift" verifies this
platform lift meets only the "private use lift"
requirements of FMVSS No. 403. This lift
may be installed on all vehicles appropriate
for the size and weight of the lift, except for
buses, school buses, and multi-purpose
passenger vehicles other than motor homes
with a gross vehicle weight rating (GVWR)
that exceeds 4,536 kg (10,000 lb).
B
A
C
NVL955IB3144
47"
40"
42"
1
Position Lift
Installation Kits
Standard Length Chassis
Vehicle
Side Door
Rear Door
Ford
30956K
30957K
GM/Chevy
30958K
*30959K
Align
(Parallel)
Vertical Arm
must clear
door opening.
Center lift in
door opening.
Side to Side Alignment
Figure B
Inboard Edge of Threshold Warning (Top) Plate
(with plate folded down)
Minimum per
18"
FMVSS No. 403
Figure C
Edge of Finished Floor or Stepwell Filler
(not outboard edge of vehicle)
Installation Kit
Extended
30955K supplied
Length
in lift parts box.
Chassis
Detailed instructions
Rear Door
supplied in kits.
30970K-42
* Rear Bumper
*30981K
Replacement Kit
19395A96 required.
Align
(Parallel)
Vertical Arm
must clear
door opening.
90
Lift towers and
vertical arms must
be parallel (aligned)
with vertical sides
of door jamb and
perpendicular (90˚)
to the vehicle floor.
18"