Ftp Server Function; Connection; Ftp Command Compliance - Fostex DV40 Supplement Owner's Manual

V1.1 supplement
Hide thumbs Also See for DV40:
Table of Contents

Advertisement

8. FTP SERVER FUNCTION

Working as a FTP (File Transfer Protocol) server, DV40 can send and receive BWF and SDII files to and
from a client PC using TCP/IP (Transmission Control Protocol/Internet Protocol). When sending and
receiving data, a FTP client application is required.

8-1. Connection

When connecting DV40 to a client PC, a "Category 5" cable which complies to 10BASE-T and
100BASE-TX must be used. If DV40 is directly connected to a client PC, a cross cable must be used.
In the case DV40 is connected to a client PC via hub, a straight cable must be used. When DV40
recognizes a client PC, the "LINK" LED on the DV40 rear panel is lit solid.
< DV40 Direct Connection >
< DV40 Connection via Hub >

8-2. FTP Command Compliance

The following FTP commands can be used when DV40 works as a FTP server.
USER
Identifying user name.
PASS
Identifying password.
QUIT
Terminating FTP connection. TCP connection for Control is also cut off.
PORT
When transferring data, relay the connection state open port number for data
transferring at client side to server.
Format: PORT IP1, IP2, IP3, IP4, P1, P2
(IPx: IP address, Px: port number represented by decimal number in every 1 byte unit)
TYPE
Designating data type (ASCII, EBCIDIC, BINARY, LOCAL).
RETR
Instructing server to trasnfer file through data connection.
STOR
Instructing server to write data transferred through data connection into a new file.
LIST
Requesting server to send a list of files.
NLST
Requesting server to send a detailed list of files.
CWD
Changing current directory.
CDUP
Changing current directory to upper level.
PWD
Displaying current directoy.
NOOP
Doing nothing.
SYST
Acquire server OS type.
To a PC
LAN Port
ANALOG INPUT BALANCED
TR3
Category 5
+4dBu
-10dBV
LINK LED is lit solid.
LAN
TR4
Cross Cable
1
1
+4dBu
-10dBV
2
2
1: GND 2: HOT
3: COLD
3
3
4
4
5
5
6
6
7
7
8
8
To a PC
Category 5 LAN Straight Cable
LAN Port
ANALOG INPUT BALANCED
TR3
1
Category 5
+4dBu
-10dBV
2
LAN
TR4
3
4
Straight Cable
5
1
1
6
+4dBu
-10dBV
2
2
7
1: GND 2: HOT
3: COLD
3
3
8
4
4
5
5
6
6
7
7
8
8
16
ANALOG OUTPUT
TIME CODE
ETHERNET
BAL [+4dBu]
TR3
TR1
INPUT
BAL [+4dBu]
TR1
THRU
UNBAL
UNBAL
+4dBu
10/100
-10dBV
[-10dBV]
[-10dBV]
BAL [+4dBu]
TR4
BAL [+4dBu]
TR2
LINK
TR2
TX/RX
1:GND
OUTPUT
2:HOT
3:COLD
15P-REMOTE
9P-REMOTE
UNBAL
UNBAL
+4dBu
-10dBV
[-10dBV]
[-10dBV]
1: GND
2: HOT
1: GND 2: HOT
3: COLD
3: COLD
Hub
ANALOG OUTPUT
TIME CODE
ETHERNET
BAL [+4dBu]
TR3
BAL [+4dBu]
TR1
INPUT
TR1
1
THRU
UNBAL
UNBAL
+4dBu
10/100
-10dBV
2
[-10dBV]
[-10dBV]
LINK LED is lit solid.
BAL [+4dBu]
TR4
BAL [+4dBu]
TR2
LINK
TR2
3
TX/RX
1:GND
4
OUTPUT
2:HOT
3:COLD
5
UNBAL
15P-REMOTE
9P-REMOTE
UNBAL
6
+4dBu
-10dBV
7
[-10dBV]
[-10dBV]
1: GND
2: HOT
1: GND 2: HOT
3: COLD
3: COLD
8
DIGITAL INPUT
VIDEO
FAN
TR4-3
TR2-1
TR1
TR2
INPUT
THRU
75
ON OFF
HI LO
DIGITAL OUTPUT
WORD
TR4-3
TR2-1
TR2
TR1
INPUT
THRU
OUTPUT
75
ON OFF
TR1
192kHz
AC IN
176.4kHz
TR2
GPI
OUTPUT
INPUT
DIGITAL INPUT
VIDEO
FAN
TR4-3
TR2-1
TR2
TR1
INPUT
THRU
75
ON OFF
HI LO
DIGITAL OUTPUT
WORD
TR4-3
TR2-1
TR2
TR1
INPUT
THRU
OUTPUT
75
ON OFF
TR1
192kHz
AC IN
TR2
176.4kHz
GPI
INPUT
OUTPUT

Advertisement

Table of Contents
loading

Table of Contents