INITIAL USE INSTRUCTIONS
ENGINE OIL
The generator is shipped
1.
Place the generator on a level surface.
2.
Pull the knob and remove the oil maintenance cover.
3.
Remove the oil filler cap/dipstick and add enough SAE 10W-30 API
service category SJ or later (or equivalent) oil to bring the oil level to
the upper limit of the oil filler neck. SAE 10W-30 oil is recommended
for general use; for additional recommendations, see page
Do not overfill the engine with oil.
excess oil may be transferred to the air cleaner case and air filter.
4.
Screw in the oil filler cap/dipstick securely.
OIL FILLER CAP/DIPSTICK
5.
Reinstall the oil maintenance cover.
WITHOUT OIL
OIL MAINTENANCE COVER
If the engine is overfilled, the
in the engine.
KNOB
50
.
UPPER LIMIT
83