Verifying Connectivity
Icon States
The DEFINITY G3 Proxy Agent maintains continuous contact with the DEFINITY
switches that it serves. When the Proxy Agent and the switch are connected, you
can determine the status of the switch by viewing the DEFINITY icons on the
network map.
If the Proxy Agent is not in contact with the switch, and
If your platform is . . .
HP OpenView
GIS StarSENTRY
NOTE:
For GIS StarSENTRY users who are upgrading DG3FM from 1.0 to 1.0.1:
For the Inform icon state to accurately represent a connection between the
switch and the Proxy Agent, you must first complete the procedure
described in the Map Merge section of this addendum.
Startup Process
You can verify connectivity when you start Fault Management from the following
screens:
Startup Screen
Switch View
Startup Screen
Verify that the Proxy Agent is connected to the switch when you start Fault
Management as follows:
1. Follow your normal startup procedure.
2. When the Fault Management Startup screen displays, examine the startup
message.
If the message is . . .
Refresh in progress, estimated delay ...
seconds, ... seconds elapsed.
Refresh on Startup Failed! Continuing
with Cached Data.
4
Issue 1 June 1995
Then the icon state is . . .
Unknown
Inform
Then the
connection is . . .
Up
Down
Need help?