An external TTL signal on pin 9 will trigger a measurement cycle. Alternatively, pin 9 of
the RS-232 interface can be connected to pin 1 through an external switch. See Figure 3-
12. A measurement cycle is trigger when the switch is closed and the +5 volts from pin 1
is applied to pin 9. The trigger event occurs on the rising edge of the signal applied to
pin 9.
Pin #
1
+5 V OUT
3
RS-232 TXD
6
Trigger Out
Figure 3-12 shows a method for using the +5 V OUT (pin 1) signal with an external
switch to trigger the Meter.

Selecting a Function Modifier

This section describes the function modifiers available with the Meter. Function
modifiers are actions that the Meter performs on an input before a reading is displayed
(for example, a comparison to another value). Function modifiers can be used in
combination. See the "Using Function Modifiers in Combination" section later in this
chapter.
To use a function modifier, press a measurement function button to select that function,
and then press the function modifier button to modify that function. (For example, press
D to select dc voltage measurement, and then press I to select the Touch Hold
function to hold the results of your measurement). Note that modified readings are shown
on the primary display only.
Table 3-4. RS-232 Pin Out
1 2 3 4
6 7 8 9
Description
+5 V Out (Pin 1)
Trig In (Pin 9)
Figure 3-12. External Trigger Circuit
Operating the Meter from the Front Panel
5
Pin #
Description
2
RS-232 RXD
5
RS-232 GND
9
Trigger In

Selecting a Function Modifier

eue23.eps
eue24.eps
3
3-17