16.5 Auto Shutdown when no Input Signal

About Auto Shutdown
When no input signal or an input signal out of specs is available on the active input module, the system starts the automatic shutdown
procedure if Shutdown mode has been enabled.
How to activate the Auto Shutdown
1. From the Installation menu, select item NO SIGNAL. (menu 16-11)
Note:
The item to change the background color in the No Signal menu is not available. For that reason the concerning text is
displayed in grey on-screen and not displayed in the graphical display.
The No Signal menu appears on-screen and in the graphical display. The No Signal menu contains 2 items, activation of the
auto shutdown and in that case setting the shutdown delay time (adjustable between 5 min and 60 min). (menu 16-12)
2. Select item SHUTDOWN [OFF] and press the ENTER key or selection Wheel to toggle the shutdown mode to ON or OFF.
If the shutdown mode has been enabled, then the shutdown time can be adjusted.
3. Select item SHUTDOWN TIME 5 MIN . (menu 16-13)
The 2 digit shutdown time is activated with the first digit ready to be changed.
4. Change the digits as follows:
-
With the Remote Control: press the cursor keys ↑ or ↓ or enter the digits directly with the digit buttons. Press ENTER to
confirm.
-
With the selection wheel on ACSAR: rotate the wheel to change the digit and press it to confirm.
5. Press EXIT (RCU) or select item RETURN (ACSAR) to return.
INSTALLATION
INPUT SLOTS
SOURCE SWITCHING
CONFIGURATION
OSD
INTERNAL PATTERNS
NO SIGNAL

QUICK ACCESS KEYS

Select with ↑ or ↓
then <ENTER>
<EXIT> to return
0HQX 
16.6 Quick Access Keys
Overview
Overview Quick Access keys
Linking a Menu to a Quick Access Key
PIP Source Quick Access Key
16.6.1 Overview Quick Access keys
About Quick Access Keys
A specific menu in the adjustment mode can be linked to a function key in order to have quick access on it.
The '0' digit on the Remote Control allows a quick entering the Pixel In Pixel (PIP) mode.
94
NO SIGNAL
COLOR [BLACK]
SHUTDOWN [OFF]
SHUTDOWN TIME 5 MIN
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
0HQX 
NO SIGNAL
COLOR [BLACK]
SHUTDOWN [ON]
SHUTDOWN TIME 05 MIN
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
0HQX 