Min Max Functions - Fluke 87V Ex User Manual

True-rms multimeter
Hide thumbs Also See for 87V Ex:
Table of Contents

Advertisement

Button
B
B
(while in MIN MAX mode)
E
PEAK MIN MAX
D
B
(hold for 1 second)
Table 7. MIN MAX Functions
Enter MIN MAX recording mode. The Meter is locked in the range displayed before you
entered MIN MAX mode. (Select the desired measurement function and range before
entering MIN MAX.) The Meter beeps each time a new minimum or maximum value is
recorded.
Step through maximum (MAX), minimum (MIN), average (AVG) and present values.
Select 100 ms or 250 s response time. (The 250 µs response time is indicated by
pon the display.) Stored values are erased. The present and AVG (average) values
are not available when 250 s is selected.
Stop recording without erasing stored values. Press again to resume recording.
Exit MIN MAX mode. Stored values are erased. The Meter stays in the selected range.
Smooth Feature (Power Up Option Only)
MIN MAX Function
True-rms Multimeter
35