27 II/28 II
Users Manual
Table 7. Functions and Trigger Levels for Frequency Measurements
Function
Range
K
6 V, 60 V,
600 V, 1000 V
K
600 mV
m L
600 mV
L
6 V
L
60 V
L
600 V
L
1000 V
R e E G
\
All ranges
AF
600 A, 6000 A
60 mA, 400 mA
^
AF
6 A, 10 A
30
Approximate
Trigger Level
5 % of scale
Most signals.
30 mV
High-frequency 5 V logic signals. (The dc-coupling of the L function can
attenuate high-frequency logic signals, reducing their amplitude enough to
interfere with triggering.)
40 mV
Refer to the measurement tips given before this table.
1.7 V
5 V logic signals (TTL).
4 V
Automotive switching signals.
40 V
Refer to the measurement tips given before this table.
100 V
Frequency counter characteristics are not available or specified for these functions.
5 % of scale
AC current signals.
30 A , 300 A
Refer to the measurement tips given before this table.
3.0 mA , 30 mA
.30 A, 3.0 A