Description - Ferroli F24 Installation, Servicing And User Instructions Manual

Gas combination boiler for central heating and hot water production, wall mounted, copper heat exchanger, fan assisted, room sealed, electronic flame ignition and control installation, service and user instructions
Table of Contents

Advertisement

Ferroli F24

1. DESCRIPTION

1.01 Introduction
The Ferroli F24 is defined as a "room sealed" combination boiler, all air required for combustion is taken from
outside the room in which it is installed. It is a new high performance gas fired heat generator for central heating and
domestic hot water production. A special feature of this boiler is its built-in electronic flame ignition and control unit
making burner operation completely automatic and safe. The main components are as follows:
• Copper heat exchanger consisting of three finned tubes specifically shaped for high efficiency.
• There are three copper coils inserted in the three heating circuit tubes. These represent the domestic
hot water heat exchanger. Their shape and high exchange surface area enable the full output of the
boiler to be absorbed.
• Ceramic fibre insulated combustion chamber
• 12 stainless steel bladed burners specifically designed for this boiler.
• Fan for discharge of combustion products and intake of combustion air.
• Differential air pressure switch. For safety reasons, this ensures the burner ignites only when the fan is functioning
correctly.
• Hermetically sealed compartment made from corrosion-resistant steel enclosing the above components.
• Combination gas safety valve with modulator, complete with pressure stabiliser.
• Flowmeter giving the domestic hot water circuit precedence over the central heating circuit.
• Pressure relief valve for the central heating circuit set to open at 3 bar.
• Built-in Expansion vessel.
• Variable speed pump.
• Central heating flow temperature adjustment thermostat.
• Domestic hot water flow temperature adjustment thermostat.
• Central heating limit thermostat.
• Overheat safety thermostat.
• Electronic control unit for automatic flame ignition and control.
• Central heating low water pressure cut off switch.
• Domestic hot water flow temperature sensor.
• Central heating flow temperature sensor.
1.02 Instructions and regulations
Assembly, installation, first start up and maintenance must be carried out by competent persons only, in accordance
with all current technical regulations and directives.
C.O.S.H.H.
Materials used in the manufacture of this appliance are non hazardous and no special precautions are
required when servicing.
Related Documents
This appliance must be installed strictly in accordance with these instructions.
The Gas Safety Regulations (Installations & Use) 1996.
The Local Building Regulations.
The Building Regulations.
The Buildings Standards (Scotland - Consolidated) Regulations.
British Standards Codes of Practice:
B.S. 7593
1992
B.S. 5546
1990
B.S. 5440
Part 1 2000 FLUES
B.S. 5440
Part 2 1989 AIR SUPPLY
B.S. 5449
1990
B.S. 6798
1987
B.S. 6891
1989
B.S. 7671
1992
B.S. 4814
1990
B.S. 5482
1994
Model Water Bye Laws
For Northern Ireland the rules in force apply
TREATMENT OF WATER IN DOMESTIC HOT WATER CENTRAL HEATING SYSTEMS
INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES
FORCED CIRCULATION HOT WATER SYSTEMS
INSTALLATION OF GAS FIRED HOT WATER BOILERS
GAS INSTALLATIONS
IEE WIRING REGULATIONS
SPECIFICATION FOR EXPANSION VESSELS
INSTALLATION OF LPG