Drilling Template (Rear Flue Application)
1. CH flow
2. Safety Valve
3. Domestic hot water outlet
4. Gas supply
5. Domestic hot water inlet
6. CH return
Select suitable mounting position
boiler, using the template mark flue
outlet and boiler mounting points. Drill
two 10mm holes 90mm deep to accept the
wall plugs, fit wall plugs. Fit two special
wall plugs on the wall as described in the
fig. 26a. Fasten the wall bracket to the
wall using an antitheft nut on the right side
and a standard nut (M8) on the left side.
Mount the boiler on the wall bracket and fix
using an antitheft nut on the left side and
a standard nut (M8) on the right side.
Using a core drill cut a 118mm diameter
hole for the flue.
Fig. 26a
280
Ø118
Ø 3/4"
Ø 1/2"
Ø 1/2"
Ø 1/2"
Ø 1/2"
1 2 3
4
5
125 min
270
21 min
Ø 3/4"
6
5 min
Fig. 26b
for
21