Dell PowerVault LTO3-060 User Manual page 23

User guide
Hide thumbs Also See for PowerVault LTO3-060:
Table of Contents

Advertisement

Key:
= OFF
= Flashing slowly
= Flashing rapidly
c. Verify that the Fault LED is flashing.
If the Fault LED is flashing, then the dump is in RAM.
n
If the Fault LED is not flashing, repeat the Service Function 2 procedure.
n
d. Press the Unload button once per second until you exit from Service mode and the Ready light comes ON solid.
Executing Service Function 3: Reserved for trained service personnel
Executing Service Function 4: Copy dump to flash
     
1. Ensure there is no cartridge in the drive.
Note:
If a cartridge is loaded in the drive, depression of the Unload button is interpreted as an unload request and the drive will ignore the second and third
depressions. The drive cannot be put into Service mode while a cartridge is loaded.
2. Press and hold the Unload button until the Ready LED begins flashing rapidly indicating Service Function 1 has been accessed. The status LEDs will be in one of
the following states.
LED icon
Key:
= OFF
= ON
= Flashing slowly
= Flashing rapidly
Important
The drive will timeout if the next step is not performed within 15 seconds.
NOTE: You can only copy dump to flash if there is a dump in RAM.
3. Press the Unload button 3 times to access Service Function 4. The status LEDs will be in one of the following states.
LED icon
Service Function 1; no drive dump
in memory
Service Function 4
LED state
Service Function 1; drive dump in
RAM
Service Function 4; drive dump in
RAM*
Service Function 1; drive dump in
flash memory
Service Function 4; drive dump in
flash memory

Advertisement

Table of Contents
loading

Table of Contents