Internal Mass Storage; Scsi Bus - HP Model 712/100 - Workstation Technical Reference Manual

9000 series 700 workstations
Hide thumbs Also See for Model 712/100 - Workstation:
Table of Contents

Advertisement

Internal Mass Storage

SCSI Bus

Application
High Use/Priority
Other devices
Medium Use/Priority
Optional Use
Low Use/Priority
When using the external SCSI configuration, you must use an active SCSI terminator at the last
external device on the SCSI bus.
All other devices, external or internal, must not be terminated.
If your workstation contains the external cable but you have no external devices, the terminator need
not be installed in the rear–panel SCSI connector. Use only HP K2291 terminators to ensure reliable
system operation.
Unit or Mass Storage Device
CPU
Root Hard Disk Drive
Most Used Hard Disk Drive
Least Used Hard Disk Drive
DDS Tape Drives
CD ROM Disk Drives
(the 712 will not support a
SCSI Floppy)
4
Recommended
Bus Address
7
6
5
4
3
2
1
0