Maytag MGR4452BDB - 4.5 GAS RANGES Installation Manual page 6

Gas 30-inch wide free-standing range
Hide thumbs Also See for MGR4452BDB - 4.5 GAS RANGES:
Table of Contents

Advertisement

!
/
//
/
TO CONNECT GAS SUPPLY TO 1/2" N.P.T.MALE INLET
SHU _ OFF
VALVE
LOWER
OV-N
TO CONNECT GAS SUPPLYTO 1/2'l N.RT. FEMALE INLET
WHEN THE INSTALLER HAS COMPLETED
INSTALLATION
OF THE APPLIANCE,
LEAVE THE APPLIANCE PRESSURE
REGULATOR
SHUT-OFF VALVE IN THE "ON" POSITION.
FLE_I/!I(
SPPL'f
LIN
\
7iiiiiiiiiG !i!!!S:i.!Pii l !ilC! :i,:! ai:i "iiiilF
:"W
i l::Rln e ::::::::::
ADApTDR
FIGURE
4
Appliance
Pressure
Regulator
& Alternate
Connectors
The appliance
pressure
regulator
on your range may
differ from this illustration.
h,
j,
Apply a non-corrosive
leak detection
fluid to all joints
and fittings
in the gas connection
between
the supply
line shut-off
valve and the range.
Include gas fittings
and joints in the range if connections
were disturbed
during
installation.
Check for leaks!
Bubbles
appearing
around fittings
and connections
will indicate
a leak. If a leak appears,
turn off supply
line gas
shut-off
valve, tighten connections,
turn on the supply
line gas shut off valve, and retest for leaks.
CAUTION: NEVER CHECK FOR LEAKS WITH A
FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF
ALL RESIDUE.
Remove
shipping
screw from ALL top burners.
(Conventional
top burner
models only). This is to hold
the burners
in place on the burner bracket
for shipping
purposes
only. (See figure 5).
Adjust
burner air shutter
to the widest opening
that will
not cause the flame to lift or blow off the burner when
cold.
NOTE:
Correctly
adjusted
sealed
burners,
can have
flames
that will lift or blow off without
a pot over the
burner.
These
should
be adjusted
with a pot in place.
FIGURE 5
CHECKING
PRESSURE
OF HOUSE
PIPING
SYSTEM
3. The appliance
and its individual
shutoff valve must be
disconnected
from the gas supply
piping system
during
any pressure
testing
of that system
at test pressures
in
excess
of 1/2 Ibs./sq.
in. (3.5 kPa) (13.8 in. water
column).
4. The appliance
must be isolated
from the gas supply
piping system
by closing
its individual
manual
shutoff
valve during any pressure
testing
of the gas supply
piping system
at test pressures
equal to or less than
1/2 Ibs./sq.
in. (3.5 kPa) (13.8 in. water
column).
-6-