REMOVING THE THERMAL FUSE & EXHAUST THERMISTOR
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Remove the rear panel (see page 4-13
for the procedure).
4.
Remove the two wires from the thermal
fuse or exhaust thermistor terminals.
5.
Remove the hex-head screw, unhook the
other end of the thermal fuse or exhaust
thermistor, and remove the component.
Exhaust
Thermistor
2 RD-WH
Viewed From Rear Of Dryer
4-12
Thermal Fuse
BK