Maytag MED5800TW - Electric Dryer Technical Education page 78

Centennial electric & gas dryers
Hide thumbs Also See for MED5800TW - Electric Dryer:
Table of Contents

Advertisement

PROBLEM: Timer Continuously
Advances
Refer to Timer Drawing, page 7-2 or 7-5; Mo-
tor Strip Circuit, page 7-3 or 7-6; and Trouble-
shooting Guide, page 6-9.
1.
Unplug dryer or disconnect power.
2.
Verify the Blue wire and the Black L1
wires are in the correct positions. See
timer illustration on page 7-2 or 7-5.
3.
Test the timer by following the proce-
dure outlined in the Diagnostic Test,
pages 6-1 & 6-2.
4.
If the timer continues to advance past
Off, replace the timer.
6-12