Maytag MED5800TW - Electric Dryer Technical Education page 77

Centennial electric & gas dryers
Hide thumbs Also See for MED5800TW - Electric Dryer:
Table of Contents

Advertisement

PROBLEM: Dryer Heats During
Air Fluff (No Heat) Cycle
Refer to Heater Strip Circuit, page 7-3 or 7-6;
and Troubleshooting Guide, page 6-9.
1.
Perform Temperature Switch Test, page
6-5.
2.
Unplug dryer or disconnect power.
3.
Check continuity of heater relay contacts.
COM to NO should be open. If not, re-
place the heater relay.
4.
With dryer fully assembled, plug in dryer
or reconnect power.
5.
Set to Air Fluff. If the dryer still heats:
Unplug dryer or disconnect power.
Replace the electronic control assembly.
PROBLEM: Dryer Won't Shut Off
Refer to Motor and Moisture Sensor Strip Cir-
cuits, page 7-3 or 7-6; and Troubleshooting
Guide, page 6-9.
1.
With the dryer fully assembled, set the
timer to Off. If the dryer starts running as
soon as it is plugged in:
Unplug dryer or disconnect power.
Replace the timer.
2.
Set the following configuration:
Dryer - power cord plugged in
Door - must be closed
Temperature switch - High
Timer - Timed Drying for less than 10 min-
utes
3.
If the dryer starts running before the Push
to Start (PTS) switch is pressed:
Unplug dryer or disconnect power.
Replace the PTS switch.
If, after replacing the PTS switch, the
dryer still starts before the PTS switch
is pressed:
Unplug dryer or disconnect power.
Replace the motor relay.
4.
If the dryer does not stop after the set
time elapses:
Unplug dryer or disconnect power.
Check the motor relay. Continuity of re-
lay should be open from COM to NO.
5.
If the dryer will not terminate its cycle
when set to Sensor Drying:
Unplug dryer or disconnect power.
Check the moisture sensor.
If there is continuity to Ground for Yel-
low-Red (Y-R) wire with no load, look
for a short in the sensor or Y-R wire.
Verify harness connections both at the
sensor and the electronic control.
If the sensor and Y-R wire are good, re-
place the electronic control assembly.
PROBLEM: Dryer Shuts Off
Before Clothes Are Dry
Refer to Moisture Sensor Strip Circuit, page
7-3 or 7-6; Thermistor Test, page 6-7; and
Troubleshooting Guide, page 6-9.
1.
Test the moisture sensor by following
the procedure outlined in the Diagnos-
tic Test, pages 6-1 & 6-2. If the moisture
sensor fails the Diagnostic Test (does not
produce a beep sound):
Unplug dryer or disconnect power.
Check the moisture sensor.
If there is continuity to Ground for Yel-
low-Red (Y-R) wire with no load, look
for a short in the Sensor or Y-R wire.
Verify harness connections both at the
sensor and the electronic control.
If the sensor and Y-R wire are good, re-
place the electronic control assembly.
2.
If Diagnostic Test is passed, verify therm-
istor by performing test procedures out-
lined in Thermistor Test, page 6-7.
3.
If problem persists after replacing mois-
ture sensor and thermistor:
Unplug dryer or disconnect power.
Replace the electronic control assembly.
6-11

Hide quick links:

Advertisement

Table of Contents
loading