5025-2xx, 4xx
Step
Questions / actions
5
Turn the printer on, and check the values at
JBIN1:
Pin
Value
4
+5 V dc
5
+0 V dc (no media), +3.3 V dc (media)
6
Ground
Are the values correct?
Fuser service check
Step
Questions / actions
1
Some low-voltage power supply FRUs have a
voltage selector switch. If it does, the switch
needs to be set to the correct voltage for your
area.
Has the LVPS been changed?
2
Turn the printer off, and remove the rear
shield. See
"Rear shield removal" on
page
4-11. Check the cable at JFUSES1 for
proper connection to the controller board, the
cable for pinch points, and the cable or
connector for any other damage.
Is the cable damaged?
3
Check the connector JLVPS1 for proper
connection to the controller board, the cable
for pinch points, and the cable or connector for
any other damage.
Is the cable damaged?
4
Check the power cable on the left side of the
fuser and the thermistor cables and
connections on the right side of the fuser.
Are the cables or connectors damaged?
2-32
Service Manual
JBIN1
Yes
Replace the fuser exit
sensor. See
"Fuser exit
sensor removal" on
page
4-30.
Yes
Check the switch on the
side of the LVPS to verify
the correct voltage is set.
Replace the fuser cable.
Repair or replace the LVPS
cable.
Repair the cables. If the
cables cannot be repaired,
replaced the fuser. See
"Fuser assembly
removal" on page
4-26.
No
Replace the controller
board. See
"Controller
board removal" on
page
4-19.
No
Go to step 2.
Go to step 3.
Go to step 4.