To The Shut-Off Valve - Whirlpool ECKMF94 - Automatic Ice Maker Installation Manual

Modular ice maker kit
Table of Contents

Advertisement

Connecting
the copper
tubing
to the shut-off
valve
Refer to the diagram below for the following
steps.
1. Straighten a 2" section of copper tubing and
make sure that the opening is round and
cut evenly across the end. If necessary, use
a tubing cutter (or a hacksaw) and cut the
end off, then file it so it is even, and remove
any burrs from around the inside and out-
side edges so it is smooth and round. When
you are finished, clean the filings from
inside the tubing as much as possible.
2. Position the compression nut as shown,
and slide it over the end of the copper
tubing.
3. Slide a compression sleeve over the
copper tubing until it is approximately
1 'from the end.
4. Insert the end of the copper tubing into the
outlet connector of the shut-off valve as far
as it will go, and then hand tighten the
compression nut as much as possible.
Compression
nut
J
r\+
)t .I
Outlet
5. Use a l/2" open-end wrench, and further
tighten the compression nut on the shut-off
valve
one additional
turn.
If necessary, you
will tighten the nut further after you turn on
the water supply.
6.Turn the T-handle on the shut-off valve to
its fully "open" (counterclockwise rotation)
position.
I
Compression
Wv=r
tubing
Connecting the copper tubing to the shut-off valve

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eckmf952155462

Table of Contents