WEIGAND FORMAT 1 – P
OCATION
(1 segment of decimal data) This location programs the Partity Type 4 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.
L
55
WEIGAND FORMAT 1 – P
OCATION
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 54 (Parity Type 4). The factory default is:
Seg 1
Seg 2
--------
--------
L
56
WEIGAND FORMAT 1 – P
OCATION
(1 segment of decimal data) This location programs the Partity Type 5 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.
L
57
WEIGAND FORMAT 1 – P
OCATION
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 56 (Parity Type 5). The factory default is:
Seg 1
Seg 2
--------
--------
L
58 – 70
OCATIONS
These locations contain the programming for Weigand Format 2. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
L
71 - 83
OCATIONS
These locations contain the programming for Weigand Format 3. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
L
84 – 96
OCATIONS
These locations contain the programming for Weigand Format 4. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
L
97 - 109
OCATIONS
These locations contain the programming for Weigand Format 5. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
L
110 - 122
OCATIONS
These locations contain the programming for Weigand Format 6. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
L
123 - 135
OCATIONS
These locations contain the programming for Weigand Format 7. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
L
136 - 148
OCATIONS
These locations contain the programming for Weigand Format 8. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
NX-1710E Single Door Control
Seg 3
Seg 4
--------
--------
Seg 3
Seg 4
--------
--------
WEIGAND FORMAT 2 (T
WEIGAND FORMAT 3 (HID1000)
WEIGAND FORMAT 4 (H10304)
WEIGAND FORMAT 5 (40
WEIGAND FORMAT 6 (40
WEIGAND FORMAT 7 (U
WEIGAND FORMAT 8 (U
T
4
ARITY
YPE
M
4
ARITY
ASK
Seg 5
Seg 6
--------
--------
T
5
ARITY
YPE
M
5
ARITY
ASK
Seg 5
Seg 6
--------
--------
ASC 27
ECOM
/F
BIT W
ACILITY CODE
/
F
BIT W
O
ACILITY CODE
)
NDEFINED
)
NDEFINED
Seg 7
Seg 8
--------
--------
Seg 7
Seg 8
--------
--------
)
BIT
– C
4001)
ASI
– C
4002)
ASI
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Networx nx-1710e

Table of Contents